SPECIFICATIONS
Function
Range
Non-contact
100 to
AC Voltage
600VAC
detector
DC Voltage
400mV
(V DC)
4V
40V
400V
600V
AC Voltage
400mV
(V AC)
4V
(50 / 60Hz)
40V
400V
600V
DC Current
400"A
(A DC)
4000"A
40mA
400mA
10A
AC Current
400"A
(A AC)
4000"A
(50 / 60Hz)
40mA
400mA
10A
Resolution Accuracy
Resolution & accuracy do not apply
since the meter does not display the
voltage in this mode. The lamp at the
top of the meter's display flashes when
voltage is sensed and an audible
warning will sound.
0.1mV
!(0.5% reading + 2 digits)
0.001V
!(1.0% reading + 2 digits)
0.01V
0.1V
1V
!(1.5% reading + 2 digits)
0.1mV
!(1.0% reading + 30 digits)
0.001mV
!(1.5% reading + 3 digits)
0.01V
0.1V
1V
!(2.0% reading + 4 digits
0.1"A
!(1.0% reading + 3 digits)
1"A
!(1.5% reading + 3 digits)
0.01mA
0.1mA
0.01A
!(2.5% reading + 5 digits)
0.1"A
!(1.5% reading + 5 digits)
1"A
!(1.8% reading + 5 digits)
0.01mA
0.1mA
0.01A
!(3.0% reading + 7 digits)
8