Craftsman 82315 Owner's Manual page 11

Mini multimeter with non-contact voltage detector (ncv)
Table of Contents

Advertisement

Storage Humidity
Operating Altitude
Weight
Size
Approvals
Safety
UL LISTED
product has been evaluated for the accuracy of its readings.
PER IEC1010 OVERVOLTAGE INSTALLATION CATEGORY
OVERVOLTAGE CATEGORY I
Equipment of OVERVOLTAGE CATEGORY I is equipment for
connection to circuits in which measures are taken to limit the
transient overvoltages to an appropriate low level. Note –
Examples include protected electronic circuits.
OVERVOLTAGE CATEGORY II
Equipment of OVERVOLTAGE CATEGORY II is energy-
consuming equipment to be supplied from the fixed installation.
Note – Examples include household, office, and laboratory
appliances.
OVERVOLTAGE CATEGORY III
Equipment of OVERVOLTAGE CATEGORY III is equipment in
fixed installations.
Note – Examples include switches in the fixed installation and
some equipment for industrial use with permanent connection to
the fixed installation.
OVERVOLTAGE CATEGORY IV
Equipment of OVERVOLTAGE CATEGORY IV is for use at the
origin of the installation.
<80% RH
7000ft. (2000meters) maximum.
9.17 oz (260g) (includes holster).
5.8" x 2.9" x 1.6" (147 x 76 x 42mm)
(includes holster)
UL, CE
This meter is intended for indoor use and
protected, against the users, by double
insulation per EN61010-1 and IEC61010-1
2nd Edition (2001) to CAT II 1000V & CAT
III 600V; Pollution Degree 2. The meter
also meets UL 61010-1, Second Edition
(2004), CAN/CSA C22.2 No. 61010-1,
Second Edition (2004), and UL 61010B-2-
031, First Edition (2003)
The UL mark does not indicate that this
11

Advertisement

Table of Contents
loading

Table of Contents