8. CONVER TING FROM ONE OPERA TING GAS TO ANOTHER
The following conversion and adjustment procedures are to be performed solely by qualified personnel. Ferroli
disclaims any liability for any material and/or personal damages caused by tampering with the appliance by
unauthorized persons. If the appliance must be used with a different type of gas, convert it as follows.
To convert the appliance from Natural gas use to Propane use and vice versa, you must change the main
injectors, adjust the maximum and minimum pressure settings of the gas valve (see related chapter), adjust the
start-up "step" as shown in fig. 12, ensuring that the jumper on the electronic board is set as shown in fig. 9.
18
Supplied By www.heating spares.co Tel. 0161 620 6677
S.p.A.
ADJUSTING THE START-UP "STEP"
Pull out the cap and set the
arrow as shown in the drawing
alongside for each type of gas
Fig. 12
NATURAL
GAS
L.P.G.