Natural Gas - Ferroli Talent Installation And Use Instructions Manual

Wall mounted fan flue gas multi-point water heater
Table of Contents

Advertisement

- Facing the appliance, the cold water inlet is on the right, the hot water outlet is on the left.
Make sure the cold and hot water systems do not serve for earthing of the electric or telephone systems. They
are not designed for this purpose. Such use might cause within a short time serious damages to the plumbing
and appliance.
5.3 Electric supply
The water heater should be powered by a single-phase 230V-50Hz current, with a 3A fuse (set between the main
power line and the water heater) and a two-pole switch with cutoff opening of 3 mm or more.
Connect the power cable provided to the main power line matching with the line, neutral and grounding wires .
If the water heater is installed in a room containing a bath or shower any electrical switch or appliance control
utilising mains electricity, should be so situated that it cannot be touched by a person using the bath or shower.
Ferroli disclaims any liability for damages to persons, animals or property caused by lack of earthing of the
heater or by an electrical system which does not comply with current regulations.
24
L
230V
50Hz
N
Key:
16 Fan
42 Temperatur sensor
43 Air pressure switch
47 Modulating regulator valve
81 Spark electrode
82 Sensor electrode
83 Full sequence automatic control
101 Main P.C.B.
129 Reset knob with lamp
136 Flowmeter
176 Security thermostat
J1 Jumper
LED1 (green)
= Power ON
LED2-5 (yellow) = Water temperature display
14
Supplied By www.heating spares.co Tel. 0161 620 6677
83
12
11
10
9
8
7
6
5
4
3
2
1
1
2
3
4
176
MAIN P.C.B. JUMPER SETTING ACCORDING TO
X5
JUMPER CONNECTS
1 AND 2

NATURAL GAS

S.p.A.
43
16
101
J1
X5
1 2
3
LED
X1
1 2 3 4 5
TYPE OF OPERATING GAS
1
2 3
Fig. 9
42
47
136
-
+
X3
X2
X5
1
2 3
JUMPER CONNECTS
2 AND 3
L.P.G.

Advertisement

Table of Contents
loading

Table of Contents