Menu Part I, Packing Details and System Feature..............2 Part II, Setup Ready To Use..................4 Part III ,System Setting By Keyboard and APP............8 Part IV, CID Monitor Center Setting................18 Part V, Query Alarm System..................21 Part VI, Default Factory Setting and System Parameters..........21 Part VII, How to Install Sensor..................22 Part VIII, Troubleshooting....................23...
Part I, Packing Details and System Feature. 1. Packing Details: 1 x Panel, 1 x PIR, 1 x Door Sensor, 2 x Remote, 1 x Power Adapter, and Few Brackets. 2. The Original Password: 1234. The password will be asked when User call or SMS to panel.
The front of the host The touch-key of the host ■Notice Display ”DISARM” Alarm host in DISARM status Display ”ARM” Alarm host in ARM status Display ”STAY ARM” Alarm host in STAY ARM status Display ”XX zone XX zone in a ARM status, display arming”...
User will be asked for password upon User Call to the host. Alarm will automatically hang up call after no operation within 20 seconds. The Operation are: [1] key: arming [2] key: disarming [3] key: monitoring open [4] key: monitoring closed [5] key: turn on announcement [6] key: turn off announcement [7] key: siren ringing...
Step 3: Power on the adapter. Add/Delete Accessories to enter main menu. Press 【2】 Press【menu】 to enter Add accessories. As Picture 5-1 Picture 5-1 1.1 Add Remote Control Press【1】to enter ‘Add Remote Control’→Input Zone Number you want to add remote control→then →...
France, Russian, Spanish, Portugal, and Chinese. It will auto-choose the language upon the language of User’s mobile device. If User’s mobile device adopt other language, the APP will auto-choose English version to install. Initial Setting as below: P1: Press Setting for font size and Language Press ‘Ok’...
Page 8
3.3 STAY Arm Stay Arm means partial protection and partial dormant. In this mode, only alarm for a part of detectors triggered. The host will display “STAY ALARM”, 3.4 Emergency alarm Emergency: Means User can force the alarm system to alarm in any working mode when emergency occurs.
slide / SMS Setting 1234+[3/4] +# (3 means relay on. 4 means off.) Part III System Setting By Panel Keyboard and APP. 1: Phone Number Setting. 1.1 Phone Number Settings The model can support 6 groups of alarm numbers, 2 groups CID numbers, 3 groups help numbers, 6 groups SMS numbers.
Page 10
alarm panel. ( The same as User send a SMS to the panel sim card: 1234 + 3 + group number + phone number +#) Remark : If panel connect with line extention, please add a ‘digit*’ before the alarm phone number. 1.1.2 Delete voice alarm phone number with two Methods: Method 1: Enter ‘1, Alarm numbers’, press...
Page 11
Method 2: from APP: Choose the one you want to delete, press 1.3.1 Set phone number to receive SMS message with two method. →choose , Press Method 1: As picture 5-2, Press and press to choose【4. SMS numbers】 press (or input【4】) to enter SMS number settings, choose group number 1-6 , then input SMS number.
Page 12
→ →choose【5. Voice calls 】press , (or press number【5】directly) As picture 5-2, Press then input number, Press to dial, press hang up the call. 2: DIY System Setting 2.1 Pre-record Voice Message Alarm panel will play a pre-recorded voice message in the alarm call. As follow: Picture 5-3 →Press As picture 5-3, press...
Page 13
Picture 5-5 → →input the date and time as picture,press As Picture 5-5, to save. Note: 2.2.1, 2.2.2 and 2.2.3 can be setting by APP page 2 Time setting : Press ‘Confirm’ to send it to Panel ‘Send’ to panel, System time will be updated SMS Setting for 2.2.1 Arm Delay : 1234+51+(0-99)+#...
Page 14
2.2.2 Alarm Delay: 1234+52+(0-99)+# 2.2.3 System Time: 1234+56+Year(4 digits)+Month(2digits)+Date(1-31)+Hour (0-23)+Minute(0-59)+Seconds(0-59)+# 2.3 Set the alarm system password with two methods Method 1: As picture 5-4, press 【2.Password Setting】, input four new password behind 【Password】 (the original password is 1234). Method 2: Change it by APP Page3: →...
Page 15
2.8 set the Internal alarm volume As picture 5-4,press 【4.Siren Setting】,→choose 【Built-in volume】→input 0-7, 7 the maximum sound→press SMS setting: 1234+87+digit (0-7)+# 2.9 Set length of Siren sound As picture 5-4,press 【4.Siren Setting】,→【Siren on time】,input 0-20 minutes.0 means no siren. SMS setting: 1234+53+Minutes(0-20)+# 2.10 Set times of rings for monitor call Picture 5-4, press 【5.Phon&SMS setting】...
Page 16
setting. Cursor to ‘Timing on/off’, press to on/off it. Method 2: Set from APP Page 2: → →Click blank Input arm/disarm time and choose the day. Click ‘OK’, Click to send. Same as SMS setting: 1234+57+Group(1-4)+Time Arm(4 digits)+Time Disarm(4digits)+ Day(1-7)+# 2.15 Set the LCD ‘Power Save’...
Page 17
3: DIY Zone Setting → On panel , enter below: Picture 5-6 3.1. Set siren ON/OFF when Alarming with two Method. → move to【Siren】 Method 1 From Panel: As picture 5-6,→input zone No.(1-99)→press →press switch ON/OFF.Off means siren not alarm for this zone→press to save.
Page 18
3.3 Set zones banded with alarm phone number. From Panel: As picture 5-6→input zones No.(1-99) →press →move to【Zone dial】→input phone number group(1-6) →press to save. ( Help zones fix to help phone number group.) 3.4 Set NO /NC for wired zone From Panel: As picture 5-6→Input wired zones No.
Part IV CID Monitor Center Setting 1, Set the phone number of CID center with 2 method: →Press →Choose CID number On Panel: Press Picture 5-2 1.1 Input Contact ID phone number to enter →choose group number (1-2)→ input CID Center phone number →Press Press save→...
Page 20
2. Set the User code for CID system → →【8.CID setting】 On Panel: Picture 5-6 2.1 Set CID User Code enter【8.CID setting】→input 4 digits CID coding behind 【User Coding】 Set On Panel: Press →press to save. Set On APP Page 3: →Click CID →...
Page 21
Set by SMS: [1234]+[91]+[0-3] +[#] 0 for No Report to CID 1 for report Arm to CID 2 for report disarm 3 for report ARM and DISARM 5. Set scheduled self-checking test time 【 8.CID setting】 →input the self check test time behind 【Test Time (4 Set On Panel: Press to enter digits)】→then press...
Part V Query Alarm System 1, Query [alarm list] or [Arm/Disarm List] record Picture 5-8 →press →press Press to History list→choose [alarm list]/ [Arm/Disarm List].The maximum 102 history record. Max 102 [Alarm List] and 72 [Arm/Disarm List] 2, Other SMS query. Query the General Parameters : SMS:[1234]+[11] +[#] Query the arm/disarm status: SMS: [1234]+[20] +[#]...
Wireless frequency : 315/433MHz GSM frequency :GSM850/900/1800/1900MHz Back-up battery:Lithium Battery 7.2V Alarm loudness:110dB Detailed parameters: Panel is compatible with Code PT2262, PT2240 and EV1527. If sensor is PT2262 encoding, the resistance must be 1.5M-4.7M; If sensor is EV1527 encoding, the resistance must be 150K-470K.
Notice: 1, Before use, make sure the PIR is powered ON. 2, Installation height is about 2.2 meters above ground 3, PIR should face the detected area for best coverage. 4, PIR should face perpendicularly to the moving of people. Installation: 1, Reinforce bracket on the wall with screws.
Page 25
5, infrared detector no work low power change to the same type battery 6, Infrared Beams not work 1、not power on Power on 2、Electrically shorted Reconnect wire 3、Beam tube dislocation Adjust beams 7, siren no sound 1. siren plug or jack in short 1.