Xtreme T90 Online 700VA User & Installation Manual

Xtreme T90 Online 700VA User & Installation Manual

T90 online series ups
Hide thumbs Also See for T90 Online 700VA:

Advertisement

Quick Links

T90 Online UPS
700VA, 1000VA, 1500VA, 2000VA, 3000VA Models
User & Installation Manual
www.xpcc.com
| © 2015 Xtreme Power Conversion Corporation. All rights reserved. (Rev 4/15/15)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the T90 Online 700VA and is the answer not in the manual?

Questions and answers

Summary of Contents for Xtreme T90 Online 700VA

  • Page 1 T90 Online UPS 700VA, 1000VA, 1500VA, 2000VA, 3000VA Models User & Installation Manual www.xpcc.com | © 2015 Xtreme Power Conversion Corporation. All rights reserved. (Rev 4/15/15)
  • Page 2: Table Of Contents

    Connecting the UPS to a Computer....................14 RS-232 Standard Interface Port.....................14 USB Port (option)...........................14 EPO Port (Emergency Power Off)....................15 Network Transient Protector......................15 Load Segments..........................15 User’s Guide To Operations................15 Starting and Shutting Down the UPS.....................15 Button Operation.......................... 15 Control Panel Functions.........................16 Xtreme Power Conversion Corporation Page 2...
  • Page 3 T90 User’s Manual Uninterruptible Power Supply Troubleshooting..........................19 Maintenance....................20 Replacing Batteries........................20 Technical Specifications................21 Terminal Block................... 22 Obtaining Service..................23 Xtreme Power Conversion Limited Warranty..........24 Xtreme Power Conversion Load Protection Policy........25 Xtreme Power Conversion Corporation Page 3...
  • Page 4: Emc Statements - Fcc Part 15

    AC power is disconnected. • CAUTION (No User serviceable Parts): Risk of electric shock, do not remove cover. No user serviceable parts inside. Refer servicing to qualified service personnel. Xtreme Power Conversion Corporation Page 4...
  • Page 5 • CAUTION (FOR 700-2000VA Only): To reduce the risk of fire. Connect only to a circuit provided with 20 amperes maximum branch circuit overcurrent protection in accordance with the National Electric Code, ANSI/NFPA 70”. Xtreme Power Conversion Corporation Page 5...
  • Page 6: Special Symbols

    RJ45 RECEPTACLE – The receptacle provides network interface connections and telephone or telecommu- nications equipment should not be plugged into it. Please do not discard the UPS or the UPS batteries as the UPS may have valve-regulated lead-acid batter- ies. Please recycle batteries appropriately. Xtreme Power Conversion Corporation Page 6...
  • Page 7: Introduction

    • DC power is converted to AC in the inverter passing it on to the load. • Power is maintained from the battery during a power failure. • The converter increases voltage appropriately for the inverter Xtreme Power Conversion Corporation Page 7...
  • Page 8: Efficiency Optimizer Function

    Backup time needed will indicate the battery size needed. If load is less than the UPS nominal power rating then actual backup time is longer. • The following options are available: » External Battery Cabinets Maintenance bypass switches » » Connectivity options (relay card, SNMP/WEB card) Xtreme Power Conversion Corporation Page 8...
  • Page 9: System Configuration

    All such operations are to be performed exactly as instructed in this manual. The greatest care possible must be taken for any of these operations and any change thereof may prove very hazardous to the operator. Xtreme Power Conversion Corporation Page 9...
  • Page 10: Storage

    • Ensure that the front of the UPS remains clear for user operation. The External Battery Cabinets may be installed next to the UPS or under the UPS. Rear Panel Views T90-700, T90-1000, T90-1500 rear view Xtreme Power Conversion Corporation Page 10...
  • Page 11 T90 User’s Manual Uninterruptible Power Supply T90i-1500 rear view T90-15HW rear view Xtreme Power Conversion Corporation Page 11...
  • Page 12 T90 User’s Manual Uninterruptible Power Supply T90-2000 rear view T90-3000 rear view Xtreme Power Conversion Corporation Page 12...
  • Page 13: Connection To Mains And Loads

    • Should computer or alarm connections be used, use connections according to the manual provided with that option. The connections can be referred to on the rear panel. The installation is now complete. Example of Installation of Plug & Play products Xtreme Power Conversion Corporation Page 13...
  • Page 14: Computer And Alarm Connections

    Connecting the UPS to your computer may be accomplished through the USB port on the back of your computer. USB compliant hardware and operating system will be necessary including installation of a UPS driver. The serial port cannot be used when using the USB port. The USB cable is standard. Xtreme Power Conversion Corporation Page 14...
  • Page 15: Epo Port (Emergency Power Off)

    Push the ON / OFF BUTTON for at least 3 seconds to turn on the UPS b. Push the ON / OFF BUTTON for at least 5 seconds to turn the UPS off Xtreme Power Conversion Corporation Page 15...
  • Page 16: Control Panel Functions

    The UPS status is shown in normal display mode. From here you have a choice to go to UPS meters display and the Setting display by pushing the button. UPS meters display Various measurements are available through the UPS meters display; pressing the button will scroll through the following meters: Xtreme Power Conversion Corporation Page 16...
  • Page 17 Input/ Select Input Voltage range when I/P Bypass Set +10/-15% +10/-15% Bypass Voltage bypass is available +15/-20% Select if UPS can run in Free run Free Run Mode Free Run Set ON/OFF mode (unsynchronized) Xtreme Power Conversion Corporation Page 17...
  • Page 18 • If UPS is on bypass and the BYPASSED LED is on, UPS will no beep. • If UPS has an internal fault and the ALARM LED is on, the UPS will give a constant audible alarm displaying the cause on the LCD display. Xtreme Power Conversion Corporation Page 18...
  • Page 19: Troubleshooting

    Site wiring Fault second tral and Ground supply without ground. See page 15 on how to disable the Site wiring alarm 1 Beep per Wrong AC Line backed up Line abnormal second during auto restart Xtreme Power Conversion Corporation Page 19...
  • Page 20: Maintenance

    2. Remove the battery cartridge from the UPS. The voltage in all models will be less than 48Vdc once the bat- tery is disconnected from the UPS. 3. Replace the batteries. 4. Push the cartridge with the new batteries back into the UPS. 5. Reinstall the metal plate and the front panel. Xtreme Power Conversion Corporation Page 20...
  • Page 21: Technical Specifications

    Technical Specifications T90-700 T90-1000 T90-2000 T90-3000 T90i-1500 MODEL NUMBER T90-1500 INPUT Capacity 700VA (490W) 1000VA (700W) 1500VA (1050W) 2000VA (1400W) 3000VA (2100W) 1500VA (1050W) Voltage range 60–144VAC** 120–276VAC** Frequency 50/60Hz auto sensing OUTPUT Voltage 208/220/ 120VAC nominal (100/110/115/127VAC selectable)*** 230/240VAC...
  • Page 22: Terminal Block

    T90 User’s Manual Uninterruptible Power Supply Terminal Block Please refer to the terminal block connection diagram to connect and use No. 14 AWG, 90°C copper wire and 8 lb-in torque force when connecting. Xtreme Power Conversion Corporation Page 22...
  • Page 23: Obtaining Service

    2. Verify there are no circuit breakers tripped. 3. Call your dealer for assistance. If you cannot reach your dealer, or if they cannot resolve the problem, call Xtreme Power Conversion Corp Technical Support at 800.582.4524. Technical support inquiries can also be made at support@xpcc.com.
  • Page 24: Xtreme Power Conversion Limited Warranty

    Any technical advice furnished by XPC Corporation or a XPC Corpora- tion authorized representative before or after delivery with regard to the use or application of Xtreme Power Con- version equipment is furnished on the basis that it represents XPC Corporations best judgment under the situation and circumstances, but it is used at the recipient’s sole risk.
  • Page 25: Xtreme Power Conversion Load Protection Policy

    T90 User’s Manual Uninterruptible Power Supply Xtreme Power Conversion Load Protection Policy THIS POLICY IS NOT A WARRANTY. REFER TO THE XPC CORPORATION, INC. LIMITED WARRANTY FOR INFORMATION CONCERNING THE WARRANTY FOR YOUR XPC PRODUCT. THE LIMITATIONS AND CONDITIONS CONTAINED IN THIS POLICY DO NOT AFFECT THE TERMS OF THE XPC LIMITED WARRANTY.
  • Page 26 Purchaser and the name of the power utility supplier for the location of the Connected Equipment. XPC will forward to the Purchaser a Load Protection Policy claims form, which Xtreme Power Conversion Corporation Page 26...
  • Page 27 No employee of XPC or any other party is authorized to make any representations beyond those made in this agreement con- cerning the Load Protection Policy. XPC Corporation 230 Yuma Street Denver, CO 80223 1.800.582.4524 Xtreme Power Conversion Corporation Page 27...

Table of Contents