Xtreme P90L User & Installation Manual

Xtreme P90L User & Installation Manual

6kva & 10kva online ups

Advertisement

P90L 6kVA & 10kVA Online UPS
6kVA, 10kVA Models
User & Installation Manual
www.xpcc.com
| © 2015 Xtreme Power Conversion Corporation. All rights reserved. (Rev 5/26/15)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the P90L and is the answer not in the manual?

Questions and answers

Summary of Contents for Xtreme P90L

  • Page 1 P90L 6kVA & 10kVA Online UPS 6kVA, 10kVA Models User & Installation Manual www.xpcc.com | © 2015 Xtreme Power Conversion Corporation. All rights reserved. (Rev 5/26/15)
  • Page 2 P90L 6kVA & 10kVA User’s Manual Uninterruptible Power Supply Please comply with all warnings and operating instructions in this manual. Save this manual and read the following instructions carefully before install- ing the unit. Do not operate this unit before reading all safety information and operating instructions carefully.
  • Page 3: Table Of Contents

    P90L 6kVA & 10kVA User’s Manual Uninterruptible Power Supply Table of Contents Safety Warnings and EMC Instructions............5 UPS Warnings..........................5 Maintenance Warnings........................5 Battery Warnings..........................5 Standards............................6 Installation....................7 UPS Unpacking and Inspection......................7 Rear Panel View..........................7 System Single Line Diagram......................10 Rack/Tower Installation.........................10 UPS Electrical Installation......................11 Operations....................13...
  • Page 4 Important Safety Warnings......................36 Installation and Setup........................36 Storage & Maintenance.........................38 Appendix B: P90L-RAIL Installation Guide...........39 Package Contents...........................39 Assembly Steps..........................39 Appendix C: P90L-ISO6MB & P90L-ISO10MB User Guide......42 Important Safety Instructions......................42 Rear Panel Explanation........................43 Installation And Operation......................44 Terminal Block Explanations for Input, Output................47 Troubleshooting..........................49 Specifications..........................49...
  • Page 5: Safety Warnings And Emc Instructions

    P90L 6kVA & 10kVA User’s Manual Uninterruptible Power Supply Safety Warnings and EMC Instructions This manual contains important instructions that you should follow during installation and maintenance of the UPS and batteries. Please read all instructions before operating the equipment and save this manual for future reference.
  • Page 6: Standards

    P90L 6kVA & 10kVA User’s Manual Uninterruptible Power Supply precautions. a) Remove watches, rings, and other metal objects b) Use tools with insulated handles. c) Wear rubber gloves and boots. d) Do not lay tools or metal parts on top of batteries.
  • Page 7: Installation

    Open the package and check the contents. The shipping package contains: • One UPS • One user manual • One 3ft, L6-30R output cord (P90L-6K only) • One 6ft, L6-30P input cord (P90L-6K only) • One monitoring software CD • One USB cable •...
  • Page 8 P90L 6kVA & 10kVA User’s Manual Uninterruptible Power Supply P90-BP240 Battery Pack Rear Panel Connection between P90-BP240 and P90L UPS Xtreme Power Conversion Corporation Page 8...
  • Page 9 7. EMBS (External Maintain Bypass Switch) port 8. Cooling fan 9. External battery connector 10. Input circuit breaker 11. Input/output terminal - P90L-6K ships with default cord kit 12. Input terminal 13. Ground 14. Output terminal 15. Battery pack output circuit breaker Note: EPO connector is normally closed (NC) for normal operation.
  • Page 10: System Single Line Diagram

    The UPS system is shipped with four plastic feet and 6 plastic extensions (2 short extensions plus 4 long exten- sions). These are to be used to install the P90L UPS or UPS and BP240 battery module in tower configuration: 1.
  • Page 11: Ups Electrical Installation

    Note 2: The wiring for P90L-6K should be able to withstand over 40A current. It is recommended to use 8AWG. Note 3: The wiring for P90L-10K should be able to withstand over 63A current. It is recommended to use 6AWG or...
  • Page 12 P90L 6kVA & 10kVA User’s Manual Uninterruptible Power Supply thicker wire for safety and efficiency. Note 4: The selections for color of wires should be followed by the local electrical laws and regulations. Note 5: External battery wires must use reinforced insulation or double insulated wire.
  • Page 13: Operations

    P90L 6kVA & 10kVA User’s Manual Uninterruptible Power Supply Operations Operating Mode/Status Description Mode/Status Description When UPS is powered on, it will enter into this mode for a few seconds for initializing UPS power on the CPU and system. When the input voltage is within acceptable range, and the UPS is turned on (the in- Line Mode verter is running), the UPS will provide pure and stable sine wave AC voltage.
  • Page 14: Led Indicators

    P90L 6kVA & 10kVA User’s Manual Uninterruptible Power Supply There are 4 buttons on front panel. Button Function • Press this button to turn on the UPS. ON/ENTER • Or press it to confirm the selection in the menu. •...
  • Page 15 P90L 6kVA & 10kVA User’s Manual Uninterruptible Power Supply ning and the UPS supplies power to the loads via bypass; (The UPS is operating in Bypass mode.) Note: When UPS is in Bypass mode, the output voltage comes directly from utility, so the load is not pro- tected by the UPS.
  • Page 16 P90L 6kVA & 10kVA User’s Manual Uninterruptible Power Supply 2. In Battery mode, you can mute the alarm by entering ”Control->Mute” on LCD to silence it. Please refer to the section of “LCD operation”. 3. The backup time depends on the external battery capacity.
  • Page 17: Lcd Operation

    P90L 6kVA & 10kVA User’s Manual Uninterruptible Power Supply LCD Operation The entire LCD structure is demonstrated in diagram below: Xtreme Power Conversion Corporation Page 17...
  • Page 18: Main Interface (Home Screen)

    P90L 6kVA & 10kVA User’s Manual Uninterruptible Power Supply Main Interface (Home Screen) 1. In the first line, it will display the current mode the UPS is in. 2. When an alarm occurs, the warning or fault information will display below the “load” line;...
  • Page 19: Control Items

    P90L 6kVA & 10kVA User’s Manual Uninterruptible Power Supply Control Items Note: “Turn On” will be displayed if UPS is not turned on. “Turn Off” will be displayed if UPS is turned on. In general situations, these items will not be displayed at the same time or in all operation modes.
  • Page 20 P90L 6kVA & 10kVA User’s Manual Uninterruptible Power Supply → → Mute This item is used to mute the buzzer in battery/bypass/fault mode. In any other mode, this item also could be seen but does not function and related data will also be shown. After confirmation, it will go to the home page and you can see the change of the mute icon.
  • Page 21: Measurement Pages

    P90L 6kVA & 10kVA User’s Manual Uninterruptible Power Supply Measurement Pages These pages display the measurement value of the parameters such as voltage / current / frequency / power / capacity / time etc. Press “UP” or “DOWN” to navigate the pages.
  • Page 22: Setting Menu

    P90L 6kVA & 10kVA User’s Manual Uninterruptible Power Supply Setting Menu This menu is used to adjust the parameters or do the calibrations. Note: Not all settings are available in every mode. If the setting is not available in present mode, the LCD will show prompt message with “Item cannot be set in this mode”.
  • Page 23 P90L 6kVA & 10kVA User’s Manual Uninterruptible Power Supply 2) ECO setting (only available or effective on bypass mode) Interface Description 1. Status Enable: Enable ECO Function Disable: Disable ECO Function If ECO function is disabled, voltage range and frequency range for ECO mode can still be set, but it is meaningless unless the ECO func- tion is enabled.
  • Page 24 P90L 6kVA & 10kVA User’s Manual Uninterruptible Power Supply 4) Battery setting (available on all operation modes) Interface Description 1. Dischg Protect: Enable: Battery discharge protection function is enabled. When UPS has been continuously working in “battery/battery test mode”, the UPS will automatically shut down when the running time set by op- tion below is met;...
  • Page 25: Alarm Page

    P90L 6kVA & 10kVA User’s Manual Uninterruptible Power Supply 5) Calibration Interface Description The Batt, Inv, and Chg calibrations can be adjusted to ensure the front panel display value matches the actual voltages measured in the UPS with a multimeter.
  • Page 26: Troubleshooting

    P90L 6kVA & 10kVA User’s Manual Uninterruptible Power Supply Troubleshooting Warning Status When Fault LED flashes and the buzzer beeps once every second, it means that the UPS has experienced a warning condition. Users can see the warning code on the LCD panel and refer to the trouble shooting table to check the warning condition.
  • Page 27 P90L 6kVA & 10kVA User’s Manual Uninterruptible Power Supply • The internal temperature is too high and has reached the warning • Make sure the ambient tempera- level: ture is not over 40°C; • Environment is too hot; • Make sure the fan is OK;...
  • Page 28 P90L 6kVA & 10kVA User’s Manual Uninterruptible Power Supply • The load is abnormal, so the inter- 04: Bus Unbal- nal positive and negative DC bus Fault • Contact the dealer. ance voltages are unbalanced; • The internal converter failed.
  • Page 29: Storage

    P90L 6kVA & 10kVA User’s Manual Uninterruptible Power Supply Storage Before storing, charge the UPS batteries for at least 7 hours. Store the UPS covered and upright in a cool, dry loca- tion. During storage, recharge the battery in accordance with the following table:...
  • Page 30: Specifications

    5 year extended warranty, power distribution (XPDU), 4-post rail kit, 2-post shelf kit, isolation trans- former with maintenance bypass 2-post shelf kit, isolation transformer with maintenance bypass *Depending on load level **P90L capacity derates 10% at 200VAC output voltage Xtreme Power Conversion Corporation Page 30...
  • Page 31: Obtaining Service

    2. Verify there are no circuit breakers tripped. 3. Call your dealer for assistance. If you cannot reach your dealer, or if they cannot resolve the problem, call Xtreme Power Conversion Corp Technical Support at 800.582.4524. Technical support inquiries can also be made at support@xpcc.com.
  • Page 32: Xtreme Power Conversion Limited Warranty

    Any technical advice furnished by XPC Corporation or a XPC Corpora- tion authorized representative before or after delivery with regard to the use or application of Xtreme Power Con- version equipment is furnished on the basis that it represents XPC Corporations best judgment under the situation and circumstances, but it is used at the recipient’s sole risk.
  • Page 33: Xtreme Power Conversion Load Protection Policy

    P90L 6kVA & 10kVA User’s Manual Uninterruptible Power Supply Xtreme Power Conversion Load Protection Policy THIS POLICY IS NOT A WARRANTY. REFER TO THE XPC CORPORATION, INC. LIMITED WARRANTY FOR INFORMATION CONCERNING THE WARRANTY FOR YOUR XPC PRODUCT. THE LIMITATIONS AND CONDITIONS CONTAINED IN THIS POLICY DO NOT AFFECT THE TERMS OF THE XPC LIMITED WARRANTY.
  • Page 34 P90L 6kVA & 10kVA User’s Manual Uninterruptible Power Supply product. Only those devices registered in that manner will be covered. 2. All Connected Equipment must be UL or CSA approved. 3. The Product must be plugged into a properly wired and grounded outlet. Use of input surge devices, ex- tension cords, adapters, ground wires, or electrical connections not manufactured by XPC voids the XPC Load Protection Policy.
  • Page 35 P90L 6kVA & 10kVA User’s Manual Uninterruptible Power Supply must be completed and filed with XPC within 30 days. • Mark the Load Protection Policy RMA number on the Product the Purchaser is returning. • Pack the Product in its original packaging or similar packing materials if the original packaging has been discarded.
  • Page 36: Appendix A: P90L-Bp240 User Guide

    P90L 6kVA & 10kVA User’s Manual Uninterruptible Power Supply Appendix A: P90L-BP240 User Guide Important Safety Warnings Please comply with all warnings and operating instructions in this manual. Save this manual properly and read carefully the following instructions before installing the unit. Do not operate this unit before reading through all safety information and operating instructions carefully.
  • Page 37 P90L 6kVA & 10kVA User’s Manual Uninterruptible Power Supply 1. DC connector : connects to either UPS or 2nd battery box 2. DC breaker: Battery over-current protection breaker 3. External battery numbers detection port: detects the numbers of connected batteries.
  • Page 38: Storage & Maintenance

    P90L 6kVA & 10kVA User’s Manual Uninterruptible Power Supply This unit can either be mounted horizontally in a rack or placed vertically on the floor. Rack Installation Tower Installation Connecting with UPS and Other Battery Box Follow below installation diagram to connect with UPS and other battery box with included cable.
  • Page 39: Appendix B: P90L-Rail Installation Guide

    P90L 6kVA & 10kVA User’s Manual Uninterruptible Power Supply Appendix B: P90L-RAIL Installation Guide Package Contents • Right rail slider x 1 • Left rail slider x 1 • Nut M6 x 6 • Screw M6 x 14 Nut M6...
  • Page 40 P90L 6kVA & 10kVA User’s Manual Uninterruptible Power Supply Step 2: Use 4 screws to mount rail sliders in back. See chart below: Step 3: According to UPS height, put nuts on proper location. Step 4: Put UPS on the rail support...
  • Page 41 P90L 6kVA & 10kVA User’s Manual Uninterruptible Power Supply Step 5: Fix the UPS in position with screws Step 6: Assembly complete Xtreme Power Conversion Corporation Page 41...
  • Page 42: Appendix C: P90L-Iso6Mb & P90L-Iso10Mb User Guide

    P90L 6kVA & 10kVA User’s Manual Uninterruptible Power Supply Appendix C: P90L-ISO6MB & P90L-ISO10MB User Guide Important Safety Instructions An Important Notice • There is a tiny leakage current from the Transformer Module, so make sure to it is correctly grounded be- fore connecting to the UPS, Utility or Output Device.
  • Page 43: Rear Panel Explanation

    P90L 6kVA & 10kVA User’s Manual Uninterruptible Power Supply Rear Panel Explanation 6kVA 10kVA RJ-45 Communication port Input & Output Terminal Block For UPS Input (6kVA only) Maintenance Bypass Switch Air Ventilation Openings (6kVA only) Thermal breaker for the protection of Load in abnormal condition: CB3 (10kVA only)
  • Page 44: Installation And Operation

    P90L 6kVA & 10kVA User’s Manual Uninterruptible Power Supply Installation And Operation UPS Unpacking • Remove the unit from PE foam. • Check Accessories one set of user’s manual one set of accessory kit RJ45 - molex cable (2) 12” NEMA L6-30P cables (6kVA only) (1) 12”...
  • Page 45 P90L-ISO6MB P90L-EBP240 1. Hardwired input from Utility Input 2. L6-30P cord from UPS input connectes to L6-30R on P90L-ISO6MB UPS Input 3. L6-30R cord from UPS connects with L6-30P on P90L-ISO6MB UPS Output 4. Hardwired TR Output to load 5. RJ45 on P90L-ISO6MB to Molex connector on P90L-6K for static bypass interlock 6.
  • Page 46 P90L-EBP240 1. Hardwired input from utility 2. Hardwired input cord with ring terminals connects to utility input terminals on P90L-ISO10MB terminal block 3. Hardwired output cord with ring terminals connets to UPS output terminals on P90L-ISO10MB terminal block 4. Hardwired output to load 5.
  • Page 47: Terminal Block Explanations For Input, Output

    P90L 6kVA & 10kVA User’s Manual Uninterruptible Power Supply Installation as a Rack Unit Terminal Block Explanations for Input, Output Terminal Block Explanation UPS Input shares Utility Input terminal L1–N1: Utility Input / UPS Input (use same terminals as Utility Input) G1: Input Ground L2–N2: Connect to UPS Output Terminal...
  • Page 48 P90L-ISO6MB Internal Jumper P90L-ISO10MB Internal Jumper Connect Maintenance Bypass Switch communication cable (C1) from RJ45 port on P90L-ISO6MB or P90L-ISO10MB to green molex connector on UPS. This prevents UPS damage should it not be in bypass prior to activating Mainte-...
  • Page 49: Troubleshooting

    Communication For Unit w/ Maintenance Bypass Detection RJ-45 connector Bypass Switch Overview 17.3 x 28.7 x 3.5 in (P90L-ISO6MB) W x D x H 17.3 x 28.7 x 5.2 in (P90L-ISO10MB) Unit w/ Maintenance 92.6 lbs 116.8 lbs Bypass Switch...

This manual is also suitable for:

P90l-iso6mbP90-iso10mb

Table of Contents