42K
110
100
90
80
70
60
50
93.2
96.8
89.6
Outdoor Temp (°F)

OPERATION DATA

Temperature Condition (°F)
Indoor
Outdoor
80/66.9
95/75
80/66.9
95/75
80/66.9
95/75
70/60
46.9/43
70/60
46.9/43
70/60
46.9/43
Notes:
Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent. (Thermistor thermometer).
Connecting piping condition: 24.6 ft.
P: pressure of air pipe connected to the indoor and outdoor units (gas valve side),
T1: Inlet and outlet temperature for evaporator,
T2: Inlet and outlet temperature for condenser.

SOUND DATA

INDOOR UNITS

09K/12K/18K Unit

Indoor side noise when running

45
40
35
30
Low
Middle
Indoor fan motor rotating speed
09K
Johnson Controls Unitary Products
Cooling
100.4
105.8
104.0
111.2
Standard
Pressure
Model name
P (MPa)
18K(9K+9K)
0.9 to 1.1
24K/30K(9K+9K+9K)
0.9 to 1.1
42K
0.9 to 1.1
18K(9K+9K)
2.3 to 2.7
24K/30K(9K+9K+9K)
2.3 to 2.7
42K
2.3 to 2.8
Super High
High
12K
120
110
100
90
80
70
60
50
40
14.0
5.0
114.8
Heat Exchanger
Pipe Temperature
T1 (°F)
T2 (°F)
COOLING
50 to 55
150 to 104
54 to 59
158 to 104
53.6 to 57.2
158 to 104
HEATING
150 to 100
35 to 40
150 to 100
35 to 40
158 to 95
33.8 to 41.0
Indoor side noise when running
55
50
45
40
35
Low
Indoor fan motor rotating speed
923212-UTG-A-0113
Heating
23.0
32.0
41.0
Outdoor Temp (°F)
Indoor Fan
Outdoor Fan
Mode
Mode
Super High
High
Super High
High
Super High
High
Super High
High
Super High
High
Super High
High
Super High
Middle
High
18K
50.0
Compressor
Frequency (Hz)
76
70
75
76
76
85
7