Resistance Tables - York DHPM09NWM42Q1 Technical Manual

Lx series ductless multi-zone split heat pumps 16 seer – 1 phase 1.5 thru 3.5 nominal tons
Table of Contents

Advertisement

923212-UTG-A-0113
Designation of Sensors
Indoor ambient temperature
Indoor tube temperature
Outdoor ambient temperature The sensor is detected to be open-circuited or short-circuited for a continuous 30 seconds.
Outdoor tube temperature
Exhaust
Overload

RESISTANCE TABLES

Resistance Table of Ambient Temperature Sensor for Indoor and Outdoor Units (15K)
Temp.(oF)
Resistance(kÙ)
-2.2
138.1
-0.4
128.6
1.4
121.6
3.2
115
5
108.7
6.8
102.9
8.6
97.4
10.4
92.22
12.2
87.35
14
82.75
15.8
78.43
17.6
74.35
19.4
70.5
21.2
66.88
23
63.46
24.8
60.23
26.6
57.18
28.4
54.31
30.2
51.59
32
49.02
33.8
46.6
35.6
44.31
37.4
42.14
39.2
40.09
41
38.15
42.8
36.32
44.6
34.58
46.4
32.94
48.2
31.38
50
29.9
51.8
28.51
53.6
27.18
55.4
25.92
57.2
24.73
59
23.6
60.8
22.53
62.6
21.51
64.4
20.54
66.2
19.63
14
Faults
The sensor is detected to be open-circuited or short-circuited for a continuous 30 seconds.
The sensor is detected to be open-circuited or short-circuited for a continuous 30 seconds.
The sensor is detected to be open-circuited or short-circuited for a continuous 30 seconds and no detection is
performed within 10 minutes after defrost begins.
After the compressor has operated for 3minutes, the sensor is detected to be open-circuited or short-circuited for a
continuous 30 seconds.
After the compressor has operated for 3minutes, the sensor is detected to be open-circuited or short-circuited for a
continuous 30 seconds.
Temp.(oF)
Resistance(kÙ)
68
18.75
69.8
17.93
71.6
17.14
73.4
16.39
75.2
15.68
77
78.8
14.36
80.6
13.74
82.4
13.16
84.2
12.6
86
12.07
87.8
11.57
89.6
11.09
91.4
10.63
93.2
10.2
95
9.779
96.8
9.382
98.6
9.003
100.4
8.642
102.2
8.297
104
7.967
105.8
7.653
107.6
7.352
109.4
7.065
111.2
6.791
113
6.529
114.8
6.278
116.6
6.038
118.4
5.809
120.2
5.589
122
5.379
123.8
5.197
125.6
4.986
127.4
4.802
129.2
4.625
131
4.456
132.8
4.294
134.6
4.139
136.4
3.99
Temp.(oF)
Resistance(kÙ)
138.2
140
141.8
143.6
145.4
15
147.2
149
150.8
152.6
154.4
156.2
158
159.8
161.6
163.4
165.2
167
168.8
170.6
172.4
174.2
176
177.8
179.6
181.4
183.2
185
186.8
188.6
190.4
192.2
194
195.8
197.6
199.4
201.2
203
204.8
206.6
Temp.(oF)
3.848
208.4
3.711
210.2
3.579
212
3.454
213.8
3.333
215.6
3.217
217.4
3.105
219.2
2.998
221
2.896
222.8
2.797
224.6
2.702
226.4
2.611
228.2
2.523
230
2.439
231.8
2.358
233.6
2.28
235.4
2.206
237.2
2.133
239
2.064
240.8
1.997
242.6
1.933
244.4
1.871
246.2
1.811
248
1.754
249.8
1.699
251.6
1.645
253.4
1.594
255.2
1.544
257
1.497
258.8
1.451
260.6
1.408
262.4
1.363
264.2
1.322
266
1.282
267.8
1.244
269.6
1.207
271.4
1.171
273.2
1.136
275
1.103
276.8
Johnson Controls Unitary Products
Resistance(kÙ)
1.071
1.039
1.009
0.98
0.952
0.925
0.898
0.873
0.848
0.825
0.802
0.779
0.758
0.737
0.717
0.697
0.678
0.66
0.642
0.625
0.608
0.592
0.577
0.561
0.547
0.532
0.519
0.505
0.492
0.48
0.467
0.456
0.444
0.433
0.422
0.412
0.401
0.391
0.382