Raymarine CP450C Installation Instructions Manual page 39

Clear pulse chirp sonar module
Table of Contents

Advertisement

LED color
LED code
Note: During a software upgrade process the LED will be solid Red and change to solid Amber on successful completion. A power cycle
will be necessary to install the changes.
Note: If any other LED sequence other than described above is seen and persists please contact Raymarine technical support.
System checks and troubleshooting
Status
Amber 6
Over voltage
blinks
(>34.2V)
Red 1 blink
General failure
Red 2 blinks
Not Defined
Red 3 blinks
Ambient temperature
too hot
Red 4 blinks
Problems with
internal database
User action
• Ensure power supply levels are consistent with
recommendations.
• If problem persists contact Raymarine technical support.
• If combined with voltage warning, check power supply and
cables.
• Power cycle unit to recover.
• If problem persists contact Raymarine technical support.
• If problem persists contact Raymarine technical support.
• Ensure installation environment is within recommendations.
• Unit will recover when temperature falls within specifications.
• If problem persists contact Raymarine technical support.
• Power cycle unit to recover.
• If problem persists contact Raymarine technical support.