Download Print this page

Goodman ComfortNet ACVC9 Technical Manual page 30

90%-95% gas furnace units
Hide thumbs Also See for ComfortNet ACVC9:

Advertisement

BLOWER PERFORMANCE SPECIFICATIONS
GCVC95/ACVC95 High (Single) Stage Cooling Speed Charts
GCVC95/ACVC95 Low Stage Cooling Speed Charts
1. Units are shipped without filter(s). CFM in chart is without filter(s).
2. All furnaces shipped with heating speed set at "B" and cooling speed set at "D". Installer should adjust blower speed
as needed. The first task is to determine the proper aiflow for the cooling system.
3. For most cooling applications, about 400 CFM per ton is desirable.
4. The chart is for information only. For satisfactory operation, external static pressure not to exceed value shown on
rating plate.
5. Do not operate above 0.5" w.c. ESP in heating mode. Operating between 0.5" w.c. and 0.8" w.c. is tabulated for cooling
purposes only.
6. * Motor CFM minimum.
30
GCVC950714CX*
ACVC950714CX*
Cooling
CFM at
Adjust
Speed
.1" - .8"
Tap
Tap
w.c. ESP
Minus(-)
594
A
Normal
660
Plus (+)
726
Minus(-)
747
B
Normal
830
Plus (+)
913
Minus(-)
1017
C
Normal
1130
Plus (+)
1243
Minus(-)
1314
D
Normal
1460
Plus (+)
1606
GCVC950714CX*
ACVC950714CX*
Cooling
CFM at
Adjust
Speed
.1" - .8"
Tap
Tap
w.c. ESP
Minus(-)
378
A
Normal
420
Plus (+)
462
Minus(-)
531
B
Normal
590
Plus (+)
649
Minus(-)
702
C
Normal
780
Plus (+)
858
Minus(-)
864
D
Normal
960
Plus (+)
1056
GCVC950915DX*
ACVC950915DX*
Cooling
CFM at
Adjust
Speed
.1" - .8"
Tap
Tap
w.c. ESP
Minus(-)
729
A
Normal
810
Plus (+)
891
Minus(-)
999
B
Normal
1110
Plus (+)
1221
Minus(-)
1287
C
Normal
1430
Plus (+)
1573
Minus(-)
1674
D
Normal
1860
Plus (+)
2046
GCVC950915DX*
ACVC950915DX*
Cooling
CFM at
Adjust
Speed
.1" - .8"
Tap
Tap
w.c. ESP
Minus(-)
504
A
Normal
560
Plus (+)
616
Minus(-)
666
B
Normal
740
Plus (+)
814
Minus(-)
828
C
Normal
920
Plus (+)
1012
Minus(-)
1071
D
Normal
1190
Plus (+)
1309

Hide quick links:

Advertisement

loading