FURNACE SPECIFICATIONS
MODEL
Btuh Input (US) High Fire
Output (US) High Fire
Btuh Input (US) Low Fire
Output (US) Low Fire
A.F.U.E.
Rated External Static (" w.c.)
Temperature Rise (°F)
High Stage Pressure Switch Trip Point (" w.c.)
Low Stage Pressure Switch Trip Point (" w.c.)
Front Cover Pressure Switch Trip Point (" w.c)
Blower Wheel (D" x W")
Blower Horsepower
Blower Speeds
Max CFM @ 0.5 E.S.P.
Power Supply
Minimum Circuit Ampacity (MCA)
Maximum Overcurrent Device
Transformer (VA)
Heat Anticipator (Amps)
Primary Limit Setting (°F)
Auxiliary Limit Setting (°F)
Rollout Limit Setting (°F)
Fan Delay On Heating
Off Heating *
Fan Delay On Cooling
Off Cooling
Fan Delay On - Fan Only
Gas Supply Pressure (Natural/Propane) (" w.c.)
Manifold Pressure (Natural/Propane) High Stage (" w.c.)
Manifold Pressure (Natural/Propane) Low Stage ("w.c.)
Orifice Size (Natural/Propane)
Number of Burners
Vent Connector Diameter (inches)
Combustion Air Connector Diameter (inches)
Shipping Weight (lbs.)
* Off Heating - This fan delay timing is adjustable (90, 120, 150 or 180 seconds), 150 seconds as shipped.
1.
These furnaces are manufactured for natural gas operation. Optional Kits are available for conversion to propane gas operation.
2.
For elevations above 2000 ft. the rating should be reduced by 4% for each 1000 ft. above sea level. The furnace must not be derated, orifice
changes should only be made if necessary for altitude.
3.
The total heat loss from the structure as expressed in TOTAL BTU/HR must be calculated by the manufactures method in accordance with the
"A.S.H.R.A.E. GUIDE" or "MANUAL J-LOAD CALCULATIONS" published by the AIR CONDITIONING CONTRACTORS OF AMERICA. The total
heat loss calculated should be equal to or less than the heating capacity. Output based on D.O.E. test procedures, steady state efficiency times
output.
4.
Minimum Circuit Ampacity calculated as: (1.25 x Circulator Blower Amps) + I.D. Blower Amps.
AMVC950453BX* AMVC950704CX* AMVC950905CX* AMVC950905DX* AMVC951155DX*
46,000
69,000
44,300
66,900
32,000
48,000
30,800
46,400
99%
95.5%
.10 - .50
.10 - .50
30 - 60
30 - 60
-0.75
-0.75
-0.30
-0.30
-0.10
-0.10
10 x 8
10 x 10
1/2
3/4
Refer to airflow charts in this manual.
115-60-1
115-60-1
11.3
14.1
15
15
40
40
0.7
0.7
145
155
150
190
170
200
30 secs.
30 secs.
150 secs.
150 secs.
5 secs.
5 secs.
45 secs.
45 secs.
5 secs.
5 secs.
7 / 11
7 / 11
3.5 / 10
3.5 / 10
1.9 / 6.0
1.9 / 6.0
#43 / #55
#43 / #55
2
3
2
2
2
2
133
157
92,000
92,000
88,800
88,800
64,000
64,000
61,700
61,700
95.7%
95.7%
.10 - .50
.10 - .50
30 - 60
30 - 60
-1.70
-1.10
-0.60
-0.50
-0.10
-0.10
11 x 10
11 x 10
1
1
115-60-1
115-60-1
14.4
14.4
15
15
40
40
0.7
0.7
130
145
120
180
200
190
30 secs.
30 secs.
150 secs.
150 secs.
5 secs.
5 secs.
45 secs.
45 secs.
5 secs.
5 secs.
7 / 11
7 / 11
3.5 /10
3.5 /10
1.9 / 6.0
1.9 / 6.0
#43 / #55
#43 / #55
4
4
2
2
2
2
172
172
AMVC95
115,000
111,100
80,000
77,400
95.8%
.10 - .50
35 - 65
-1.10
-0.50
-0.10
11 x 10
1
115-60-1
14.4
15
40
0.7
150
200
200
30 secs.
150 secs.
5 secs.
45 secs.
5 secs.
7 / 11
3.5 /10
1.9 / 6.0
#43 / #55
5
2
2
184
17