BLOWER PERFORMANCE SPECIFICATIONS
GCVC95/ACVC95 Heating Speed Charts
GCVC950714CX*
ACVC950714CX*
(Rise Range: 25 - 55°F)
Low Stage
Heating
Adjust
Speed
Tap
at .1" - .5" w.c.
Tap
Minus(-)
A
Normal
Plus (+)
Minus(-)
B
Normal
Plus (+)
Minus(-)
C
Normal
Plus (+)
Minus(-)
D
Normal
Plus (+)
1. Units are shipped without filter(s). CFM in chart is without filter(s).
2. All furnaces shipped with heating speed set at "B" and cooling speed set at "D". Installer should adjust blower speed
as needed. The first task is to determine the proper aiflow for the cooling system.
3. For most cooling applications, about 400 CFM per ton is desirable.
4. The chart is for information only. For satisfactory operation, external static pressure not to exceed value shown on
rating plate.
5. Do not operate above 0.5" w.c. ESP in heating mode. Operating between 0.5" w.c. and 0.8" w.c. is tabulated for cooling
purposes only.
6. * Motor CFM minimum.
28
High Stage
CFM
CFM
at .1" - .5" w.c.
ESP
ESP
783
1107
870
1230
957
1353
855
1215
950
1350
1045
1485
936
1323
1040
1470
1144
1617
1017
1440
1130
1600
1243
1760
(Rise Range: 25 - 55°F)
Heating
Rise
Adjust
Speed
(°F)
Tap
Tap
55
Minus(-)
49
A
Normal
45
Plus (+)
50
Minus(-)
45
B
Normal
41
Plus (+)
46
Minus(-)
41
C
Normal
37
Plus (+)
42
Minus(-)
38
D
Normal
34
Plus (+)
GCVC950915DX*
ACVC950915DX*
Low Stage
High Stage
CFM
CFM
at .1" - .5" w.c.
at .1" - .5" w.c.
ESP
ESP
1008
1458
1120
1620
1232
1782
1098
1575
1220
1750
1342
1925
1152
1674
1280
1860
1408
2046
1206
1773
1340
1970
1474
2167
Rise
(°F)
55
50
45
51
46
42
48
43
39
45
41
37