Routine Lubrication - Max-Ox MX-900B Operator's Manual

Commercial wood chip-fired hydronic boiler
Table of Contents

Advertisement

11. Clean and lubricate the ash ring as follows: Wearing gloves,
manually lift the heavy steel ash ring upward from the stoker rear door
side, and push outward towards the stoker front door. The rig is
heavy, and therefore removal is best performed with two people.
Brush off all surfaces of the ash ring, and lubricate the inside bore of
the ash ring with dry film bonded molybdenum disulphide spray.
Reinstall the ash ring.
12. Clean the cyclone ash container as follows: Manually close the slide
gate above the cyclone as container. Un-latch the ash container, and
dispose of its ash contents properly. Reinstall the ash container and re-
latch. Open the manual slide gate and tighten its thumbs screw.
Note: open the manual slide gate prior to re-installing the ash
container in order for the ID Fan draft to assist in seating the ash
container against its gasketed lid.
13. Stop the ID Fan and re-set its minimum speed to 13 Hertz.
14. Clean the Ash Bin (ash auger bin) as follows: un-latch the ash bin
from the ash auger trough. Dispose of the contents properly. Re-install
and latch the Ash Bin.
15. Vacuum any fugitive ash dust from around the MX-900B.

Routine Lubrication

ID Fan Bearings: Every 3 months of operation, add high quality high
temperature grease to both ID Fan shaft pillow block bearings using a grease
gun.
Ash Auger Drive Train: Every 3 months of operation, add high quality high
temperature grease to both Ash Auger Drive Train grease zerk fittings
located on the stoker base adjacent to the ash auger drive motor gear box and
chain sprocket.
Max-Ox™ MX-900B Operators Manual, Rev. 0
Page 52 of 54