Max-Ox MX-900B Operator's Manual page 30

Commercial wood chip-fired hydronic boiler
Table of Contents

Advertisement

Note: The Feed Auger will commence transfer of fuel into to the stoker.
The elapsed time required to fill the fuel Feed Auger tube is
approximately 3 to 5 minutes. Fuels with high density will take longer to
fill the auger tube than will fuels of low density.
17. Open the front access door to the stoker unit (door with viewing
window)
18. Continue to monitor Feed Auger performance. Permit the Feed Auger
to push fuel up onto the stoker grate until a pile approximately 8 to 10
inches in diameter forms.
19. Immediately shut off the Feed Auger by pressing the "Stop" icon.
20. Fully close the Secondary and Tertiary air gates.
21. Fully open the Primary air gate
22. Ignite the top of the fuel pile with a hand-held Propane or Mapp™ gas
torch in three locations across the surface of the fuel pile.
23. Close and latch the stoker unit front access door
24. Observe the fuel pile through the front door viewing window until
fuel pile is well ignited.
25. Press the Feed Auger "SP" (set-point) icon
26. On the Keypad screen, enter a value of 50 (percent)
27. Press the Feed Auger Speed Control "Manual" icon
Max-Ox™ MX-900B Operators Manual, Rev. 0
Page 30 of 54

Advertisement