Arming using PS1 or keyswitch
The PS1 bedside remote arming module or keyswitch can be used to stay arm, full arm, or disarm the
system. The PS1 keyswitch is enabled at address 086, key [3].
Key [2] "off": PS1 or keyswitch "regular" arms system.
Key [2] "on": PS1 or keyswitch "stay" arms system.*
*Note: If partitioning is enabled (address 086, key [8] "on"), PS1 arms system "A" only. Use of PS1 is not
recommended for partitioned systems.

Call back

For extra security, the panel can be programmed to call the PC back when communication is attempted
by the PC. The panel will first answer the call, then Espload and the panel will verify identification codes.
The panel will then hang up and call the PC back and establish communication. Espload automatically
goes into the "wait for call mode", ready to answer when the panel calls back. The identification codes
are verified again before allowing access to the panel.
Related features:
"Computer telephone number" 008-015.

Auto arm

On Time:
The panel may be programmed to arm at the same time every day. Program both the hour and minute
(addresses 044, 045) for arming. A late closing code may be programmed (address 516).
Related features:
" Auto arm" 090, [2]
No Movement:
If zone activity is not detected for a programmed period (address 055) while disarmed, the panel can auto
arm and/or send a "no movement" report (address 517). Refer also to "No movement" p. 15.

Touch tone options

Tone (key [7] = "on") or pulse dialing can be programmed. If "pulse" is chosen for a central station phone
number, "tone" dialing can be programmed for the other number. [
should be entered in the second phone number during programming.
Partitioning
Partitioning is activated, (key [8] "on"). The panel's fully programmable zones (plus 2 remote keypad
zones) can be divided into two systems. (See "System Partitioning", page 25.)

Silent alarm

Key [9] "off":
Silent zones/panics generate a silent alarm. Zones defined as "silent" at addresses 096-098 and keypad
panic zones will not cause an audible alarm, however, the keypad "armed" light will flash and the alarm
condition will remain until a valid user code is entered.
Key [9] "on":
Silent zones/panics generate only a report (The red keypad LED does not flash, and there is no need to
"reset" the silent alarm.)
Silent delay zones generate an entry delay beep, and a report at the end of the entry delay.
Zone restore is always reported upon zone closure.
Memory display, auto zone shutdown are always active for silent zones when enabled at address 086, key [
Silent alarms can be monitored by a PGM output. (Silent flag is cleared on report or disarm.)
On split reporting, silent zones/panic are reported to Telephone #1.

Dialing pulse rates

This selection reflects the ratio between "pulse" time and "quiet" time. Select Pulse Europe for a 1:2 ratio
(Key [10] = "off"), Pulse USA for 1:1.5. (Key [10] = "on")

Reporting options

Regular reporting
To activate central station reporting, the feature must be enabled and all required reporting codes, except
when using "Ademco contact ID (all codes reported)", must be assigned a value other than [2
(Address 086, key [2] and key [3])
(Address 086, key [4])
(Address 086, key [5])
"Auto/Espload Arm" 300
(Address 086, key [6])
(Address 086, key [7])
(Address 086, key [8])
(Address 086, key [9])
(Address 086, key [10])
(Address 086, key [11] "off" and key [12] "on")
18
"Auto arming" p.15 .
] ("switch from pulse to tone")