Maximum recommended flown configurations are summarized as follows:
dV-BUMP ONLY
(SINGLE POINT HANG FROM CENTRAL SPREADER BAR POINTS)
- maximum 24 dV-DOSC elements
dV-BUMP + EXTENSION BAR
(SINGLE POINT HANG FROM REAR EXTENSION BAR POINTS)
- maximum 12 dV-DOSC elements
dV-BUMP + EXTENSION BAR
(2 POINT HANG FROM dV-BUMP FRONT POINT AND EXTENSION BAR REAR POINT)
- maximum 12 dV-DOSC elements
With dV-DOWN, up to a maximum of 6 dV-DOSC can be flown underneath V-DOSC for downfill
applications. Three dV-DOSC are equivalent to the weight of one V-DOSC, therefore maximum
cabinet combinations include: 15 V-DOSC plus 3 dV-DOSC or 14 V-DOSC plus 6 dV-DOSC.