Back Panel; Pa-3020 And Pa-3050 Back Panel - PaloAlto Networks PA-3020 Hardware Reference Manual

Table of Contents

Advertisement

Back Panel

Back Panel
This section describes the back panel of the PA-3000 Series firewalls.
"PA-3020 and PA-3050 Front Panel" on page 6
"PA-3060 Front Panel" on page 7

PA-3020 and PA-3050 Back Panel

Figure 3 shows the back panel of the PA-3020 and PA-3050 firewalls and Table 3 describes the
back-panel features.
Figure 3. PA-3020 and PA-3050 Back Panel
AC Power
Inlet
Power Supply
Exhaust
Table 3. PA-3020 and PA-3050 Back-Panel Features
Item
AC power inlet and power
supply
Grounding lug
8 • Overview
Grounding
Lug
Description
Power inlet for device power. 
Note: The power supply is not customer serviceable.
To ground the system, use a grounding wire of at least 14 American
Wire Gauge (AWG). Attach the 14 AWG wire to an agency-
approved crimp connector (Tyco 34120 or certified Lug), crimped
with the proper crimping tool and attached to the protective
grounding lug. Use a size #8-32 nut and a star washer (supplied) to
secure the grounding lug to the chassis and connect he other end to
the building ground. Toque the nut to 15 in-lbs. Do not over tighten.