Initial Oil Fill; Wh1000I - Westinghouse WH1000i Owner's Manual

Digital inverter generator
Hide thumbs Also See for WH1000i:
Table of Contents

Advertisement

Available languages

Available languages

2. Start one of the inverters and wait until the ready
light is on.
3. Turn both cord switches to ON (I).
4. Start the remaining inverter; wait until the ready
light is on before connecting the load.
5. When power is present, a light will illuminate in the
three-prong plug that is plugged into the inverter.
Figure 15 – Paralleling Cord Connected
6. To stop the inverters, unplug all connected loads,
turn both cord switches to OFF (O) and unplug the
cord on each inverter.
7. If during operation the inverters' output is stopped
due to overloading, reduce the connected load by
unplugging appliances, and then push the reset
button and restart the inverter. When the ready light
is on, the load can be reconnected.

INITIAL OIL FILL

NOTICE
Engine oil must be added when the inverter is on
a flat, level surface, or an inaccurate reading may
result. Do not overfill. If the engine is overfilled with
oil, it can cause serious engine damage.
OPERATION

WH1000i

1. Loosen the screw and remove the engine service
panel to access the oil fill/drain plug
Figure 16 – WH1000i Engine Service Panel
2. Clean area around oil fill/drain plug and remove
plug
(see Figure 17).
Figure 17 – Oil Fill/Drain Plug
N
OTE:
The oil capacity for the 1000i is 300 ml.
(see Figure 16).
25

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Wh2000i series

Table of Contents