Access To The Expert Level; Code List; Functional Check - Siemens REV24RF User Instruction

Rev24rf series radio set with 7-day room temperature controller
Hide thumbs Also See for REV24RF:
Table of Contents

Advertisement

Note
on reception
No reception
J DIP switch reset
ON
1
2
3
4
5
6
7
8
9

Access to the expert level

Set the program selection slider to RUN. Press
within 3 seconds press and hold down
seconds. This releases the engineering settings.
The display first shows language selection with Code 00. Press the buttons
Confirm settings by pressing
Press the operating mode selector

Code list

Function block
Code
00
Basic settings
01
02
10
LCD
11
optimization
12
30
Clock settings
31
32
Note 1:
Note 2:
Note 3:

Functional check

9 / 18
Siemens
Building Technologies
The time signal from Frankfurt is modulated to a radio signal. The reception of this radio
signal depends on the distance to Frankfurt, atmospheric conditions as well as the
location where the REV..DC is installed. Siemens cannot guarantee that the REV..DC
can receive the time signal from Frankfurt at any time and any place.
The radio clock symbol is deactivated and an error message is displayed if the clock was not
able to synchronize the time for 7 consecutive days. The controller then runs on the internal
quartz.
After you change one or several DIP switch positions, you must press the DIP switch
reset button to reset the DIP switch.
Otherwise, the previous setting remains active!
and
and
simultaneously for 3 seconds, release
.
to exit the engineering settings.
Name
Language
Sensor calibration
Switching differential 2-point
Illumination time
Background brightness
Contrast
Time zone
Deviation from time signal in Frankfurt
(Central European Time CET) (see Note 1)
Start of daylight saving time (see Note 2)
End of daylight saving time (see Note 3)
This entry has no effect if the radio clock either is inactive or not available.
The time signal received from Frankfurt is shifted by the value set in Code 30 (time zone)
if the radio clock is active.
The time is always changed over at 2 a.m. on the Sunday preceding the set date if there
is no radio clock or if it is inactive. The time change is shifted by the value set in Code 30
(time zone) when the radio clock is active.
The time is always changed over at 3 a.m. on the Sunday preceding the set date if there
is no radio clock or if it is inactive.
a)
Check the display. If there is no display, check insertion and function of the batteries.
b) Operating mode "Continuous comfort mode"
c)
REV.. in heating mode: Set the temperature setpoint higher than the displayed room
temperature (see operating instructions).
REV.. in cooling mode: Set the temperature setpoint lower than the displayed room
temperature (see operating instructions).
Room temperature controller radio set REV24RF../SET
simultaneously for 3 seconds, release the buttons, and
is displayed.
or
Factory setting
English
off
0.5 °C
10 seconds
0
0
0 hours
March 31 (03-31)
October 31 (10-31)
, read displayed temperature.
, and press
for another 3
to navigate the settings.
Your setting
CE1N2206en
24.04.2008

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rev24rfdcRcr10/868

Table of Contents