7-day
room temperature controller
Heating applications
Mains-independent, battery-operated room temperature controller featuring
user-friendly operation, easy-to-read display and large numbers.
3-position controller with PI mode and optimum start control.
Possibility to adapt volume and control gain.
Operating mode selection:
- 7-day automatic mode with max. 3 heating phases.
- Continuous comfort mode.
- Continuous energy saving mode.
- Frost protection.
- Exception day (24 hour operation) with max. 3 heating phases.
A separate temperature setpoint can be entered in automatic mode and for
the exception day for each heating phase.
Heating zone control.
Room temperature control in:
∂ Single-family and vacation homes.
∂ Apartments and offices.
∂ Individual rooms and professional office facilities.
∂ Commercially used spaces.
To control electric 3-position actuators with a running time of 120....150 seconds,
for use with stroke and rotary actuators.
2
208
REV34..
Building Technologies

Advertisement

loading

Summary of Contents for Siemens REV34 Series

  • Page 1 7-day REV34.. room temperature controller Heating applications ∂ Mains-independent, battery-operated room temperature controller featuring user-friendly operation, easy-to-read display and large numbers. ∂ 3-position controller with PI mode and optimum start control. ∂ Possibility to adapt volume and control gain. ∂ Operating mode selection: - 7-day automatic mode with max.
  • Page 2 1.5 V alkaline batteries, type AA. The base with terminal block provides lots of space to connect the wires. Display and operating elements 2 / 15 Siemens Room temperature controller REV34.. CE1N2208en Building Technologies 2017-11-15...
  • Page 3 The unit first displays queued error messages followed by important information (e.g. time switch programs, etc.). Plus button Increase values, set time, or make a selection. 3 / 15 Siemens Room temperature controller REV34.. CE1N2208en Building Technologies 2017-11-15...
  • Page 4 Start of absence / holiday Temperature setpoint during absence / holiday End of absence / holiday Temperature setpoint at active remote control Slider position RUN allows for closing the cover 4 / 15 Siemens Room temperature controller REV34.. CE1N2208en Building Technologies 2017-11-15...
  • Page 5 6…7. As a result, you need to adapt the switching times and room temperatures only once for each block. Switching pattern Blocks You can also enter individual days … 5 / 15 Siemens Room temperature controller REV34.. CE1N2208en Building Technologies 2017-11-15...
  • Page 6 Proceed as follows to enter your settings: Set slider to temperature position for active remote control: Press set the desired temperature for active remote control. RUN Return the slider to position RUN. 6 / 15 Siemens Room temperature controller REV34.. CE1N2208en Building Technologies 2017-11-15...
  • Page 7 ½ h/°C For medium controlled systems. DIP switches 4 OFF and 5 OFF: OFF Off, no effect (factory setting). Press the DIP switch reset button to save the settings. 7 / 15 Siemens Room temperature controller REV34.. CE1N2208en Building Technologies 2017-11-15...
  • Page 8 Frankfurt, Germany. Synchronization takes max. 10 minutes. Synchronization restarts each time you press the button or move the program selection slider from the RUN position during these 10 minutes. Siemens recommends to set the desired settings 8 / 15 Siemens Room temperature controller REV34..
  • Page 9 Frankfurt, atmospheric conditions as well as the on reception location where the REV..DC is installed. Siemens cannot guarantee that the REV..DC can receive the time signal from Frankfurt at any time and any place.
  • Page 10 CLOSED. Driving the actuator to the fully CLOSED position takes max. 150 Important: seconds. After a reset, reinsert the controller in the base within 30 seconds. 10 / 15 Siemens Room temperature controller REV34.. CE1N2208en Building Technologies 2017-11-15...
  • Page 11: Select Operating Language

    (as needed), date, comfort phases, etc.. Notes This is a software class A controller designed for use at a normal degree of pollution. 11 / 15 Siemens Room temperature controller REV34.. CE1N2208en Building Technologies...
  • Page 12 II as per EN 60 730-1 NTC 10 kς ς1 % at 25 °C Sensing element Measuring range 0…50 °C Time constant Max. 10 min Setpoint setting ranges All temperature settings 3…35 °C 12 / 15 Siemens Room temperature controller REV34.. CE1N2208en Building Technologies 2017-11-15...
  • Page 13 0.32 kg Color Housing RAL9003 signal white Base RAL7038 gray Size Housing with base 90 x 134.5 x 30 mm *) The documents can be downloaded from http://siemens.com/bt/download 13 / 15 Siemens Room temperature controller REV34.. CE1N2208en Building Technologies 2017-11-15...
  • Page 14: Instantaneous Water Heater

    Application examples F1 F2 Instantaneous water heater Zone valve REV34.. room temperature controller Burner Three-port valve with actuator Thermal reset limit thermostat Circulating pump Manual reset safety limit thermostat 14 / 15 Siemens Room temperature controller REV34.. CE1N2208en Building Technologies 2017-11-15...
  • Page 15 Dimensions Issued by © Siemens Switzerland Ltd, 2008 - 2017 Siemens Switzerland Ltd. Technical specifications and availability subject to change without notice. Building Technologies Division International Headquarters Gubelstrasse 22 CH-6300 Zug Tel. +41 58-724 24 24 www.siemens.com/buildingtechnologies 15 / 15 Siemens Room temperature controller REV34..