Download Print this page

Aktakom AM-1083 User Manual page 4

Digital multimeter

Advertisement

4. The screen will show the voltage measured if touch the testing point
using the pencils; the point touched by the red pencil is in positive
voltage if the value showed is positive.
Notice:
1. As showed, "OL" indicates the range is over and shall switch to a
higher range.
2. The voltage to be tested shall not over DC 1000V or AC 750V. The
pencils shall be away from the testing point as switching functions or
ranges.
3. When measuring high voltage circuit, any parts of your body should
not touch the high voltage circuit, otherwise it may hurt your body.
5-3. Current measurement
1. Insert the black pencil into the "COM" jack, and the red one into the
"mA" or "20A" jack.
2. Turn the switch to position "A". If the level of current to be measured
is unknown then select the biggest range and then decrease the
range step by step until getting the value with the highest resolution.
3. Popup the key "DC/AC" to enter into DC mode if measuring DC; press
down the key "DC/AC" to set into AC mode.
4. The screen will show the value of current measured if connect in
parallel the pencil to the circuit to be tested; the point touched by the
red pencil is in positive voltage if the value showed is positive.
Notice:
1. As showed, "OL" indicates the range is over and shall switch to a
higher range.
2. The input in "mA" jack shall not over 200mA and "20A" not over 20A
(less than 10 seconds of testing duration) as measuring current; the
pencils shall be away from testing points as switching function or
range.
5-4 Resistance measurement
1. Insert the black pencil into the "COM" jack, and the red one into
the "V/Ω/Hz" jack;
2. Turn the range switch to resistance position, then bride two
pencils at the two ends of the resistor.
Notice:
1. "OL" will be displayed in screen if the resistance is over the range,
then you shall increase the range by one step;
2. When input is open circuit, it will display status of overload;
3. When measuring resistance on line, ensure that all power of circuit
tested are turn down and all capacitor are discharged completely;
4. Never input voltage if in resistance measurement mode!
5. It normal for resistance higher than 1MΩ that the reading data is not
stable for the first several seconds;
5-5 Capacitance measurement
1. Switch to a proper range, and insert pencils into "mA" and "com" jack.
2. Connect the two pencils in parallel to the two ends of the capacitor.
Please pay attention to the polarity, as the "com" for positive and
"mA" for negative.
Notice:
1. If capacitance exceeds the range selected, "OL" will be displayed in
screen,then you shall increase the range by one step.
2. The LCD may show some rudimental digits upon the starting of
capacitance measurement. It's normal and will not affect the testing
www.tmatlantic.com
result;
3. If there is serious creepage or capacitor broken down in high
capacitance range, the digits showed will be random and unstable.
4. Please discharge capacitor completely to avoid device damage
before measuring capacitance.
5-6. Inductance measurement
1. Switch to a proper range, and insert pencils into "mA" and "com" jack.
2. Bridge the pencils on the two ends of inductor.
Notice:
1. If inductance exceeds the range selected, "OL" will be displayed in
screen,then you shall increase the range by one step.
2. The inductance value measured for identical inductor may be
different if there is different impendence;
3. If in range 2mH, please short pencils and measure lead inductance,
and then subtract the inductance from the value measured.
4. Avoid measuring small inductor in high range, or the accuracy is not
guaranteed.
5-7. Temperature measurement
Turn range switch to " ", insert the cathode(black pin) of cold
end (free end) of thermocouple into "mA" jack, anode (red pin) into
"COM" jack, put the working end (temperature measurement end) of
thermocouple on the surface or inside the object to be tested. Then
you can read temperature from the screen, and the data is in
centigrade.
Notice:
1. As the input end is open, it will show environment temperature if the
operation temperature is higher than 18 , or normal temperature if
lower than 18 .
2. Please never replace temperature sensor, or the accuracy is not
guaranteed;
3. Never input voltage if in temperature mode.
5-8. Frequency measurement
1. Insert pencils or shielded cable into "COM" and "V/Ω/Hz" jack;
2. Turn range switch to frequency position and bridge pencils or cables
over the signal source or load tested.
Notice:
1. The device can still work if the input is higher than 10V virtual
value, but the accuracy is not guaranteed;
2. In noise environment, you'd better use shield cable to measure
small signal;
3. When measuring high voltage circuit, any parts of your body
should not touch the high voltage circuit, otherwise it may hurt
your body.
4. Never input voltage higher than 250V DC or AC peak value,
otherwise it may damage your device.
5-9. Triode hFE
1. Turn the range switch to "hFE" position;
2. Insert testing accessory into "mA" and "com" jack. Please pay
attention to the polarity, as the "com" for positive and "mA" for
negative.
3. To determine the triode's type, NPN or PNP, insert the emitting, base
and collector electrode into the corresponding jacks in testing
accessory.

Advertisement