SYSTEM
PERFORMANCE
Model Numbers
RIO09HP115V1A
RIO12HP115V1A
RIO09HP230V1A
RIO12HP230V1A
RIO18HP230V1A
RIO24HP230V1A
Model Numbers
HSPF
RIO09HP115V1A
RIO12HP115V1A
RIO09HP230V1A
RIO12HP230V1A
RIO18HP230V1A
RIO24HP230V1A
NOTES:
1. Ratings are based on: Cooling Standard: 80 F (26.7 C) db, 67 F (19.4 C) wb air entering indoor unit and 95
F (35 C) db air entering outdoor unit. Heating Standard: 70 F (21.1 C) db air entering indoor unit and 47 F
(8.3 C) db, 43 F (6.1 C) wb air entering outdoor unit.
2. Ratings are based on 25 ft. (7.62 m) of interconnecting refrigerant lines.
3. All system ratings are based on fan coil units operating at high fan speed. Consult Physical Data tables for
air flows at selected fan speeds.
Legend
EER - Energy Efficiency Ratio
HSPF - Heating Seasonal Performance Ratio
SEER - Seasonal Energy Efficiency Ratio
COP - Coefficient of Performance
SEER
EER
Rated
(BtuH)
16
12.0
9,000
16
9.4
11,800
16
10.2
9,000
16
9.8
12,000
16
11.1
18,000
16
10.0
22,000
COP
Rated
(BtuH)
3.5
8.6
9,800
2.9
8.6
13,000
3.4
8.5
9,000
3.4
8.5
12,000
2.8
8.0
19,200
8.5
3.0
24,200
© 2014 Gree Electric Appliance, Inc.
Cooling Capacity
Range
(BtuH)
(3,500-11,000)
(3,300-12,500)
(3,800-11,500)
(3,300-12,500)
(4,500-21,000)
(6,400-24,000)
Heating Capacity
Range (BtuH)
(2,500-11,000)
(3,400-13,500)
(3,300-11,500)
(3,400-12,500)
(4,000-23,000)
(4,100-26,600)
Outdoor
Dehumid-
Temperature
ification
Operating Range
(Pts./Hr.)
Min
1.7
64 °F
2.9
64 °F
1.7
5 °F
2.9
5 °F
3.8
5 °F
4.2
5 °F
Outdoor Temperature
Operating Range
Min
5 °F
5 °F
5 °F
5 °F
5 °F
19 °F
Max
113 °F
113 °F
109 °F
109 °F
109 °F
109 °F
Max
75 °F
75 °F
75 °F
75 °F
75 °F
75 °F