Cisco AIR-LAP1310G Mounting Instructions page 14

Cisco aironet 1300 series lightweight outdoor access point
Hide thumbs Also See for AIR-LAP1310G:
Table of Contents

Advertisement

Mounting the Access Point
Mount the access point using the following user-provided hardware:
Step 4
Note
Tighten the bolts to secure the access point mounting bracket to the wall or ceiling.
Step 5
Mounting the Power Injector on the Access Point
When using the wall or ceiling mounting bracket, you can mount the power injector directly on the
access point mounting lugs (see
When mounted together, the access point and power injector must be mounted in a sheltered indoor
Note
environment.
Figure 3
The following hardware used to mount the power injector on the access point is supplied with the wall
or ceiling mounting bracket kit:
Cisco Aironet 1300 Series Lightweight Outdoor Access Point Mounting Instructions
14
Wooden structure—three 1/4 x 1 inch (minimum) lag bolts
Hollow walls—three 1/4-20 x 2 3/4 molly anchors
Concrete structure—three 1/4 x 1 inch (minimum) bolts with concrete anchors
Examine the structure to ensure that the mounting location is not deteriorating or weak. You are
responsible for ensuring that the mounting location can adequately support the access point.
Mounting the Power Injector on the Access Point
Four hex head bolts with serrated flange (M6x1x10 mm)
Four washers
Figure
3) using the hardware included with the bracket.
78-17634-01