Compressor Checking; Ipm Continuity Check - Vivax ACP-09CH25AELI Service Manual

Hide thumbs Also See for ACP-09CH25AELI:
Table of Contents

Advertisement

2.Compressor checking

Measure the resistance value of each winding by using the tester.
Position
Blue - Red
Blue - Black
Red - Blue

3.IPM continuity check

Turn off the power, let the large capacity electrolytic capacitors discharge completely, and dismount the IPM. Use a
digital tester to measure the resistance between P and UVWN; UVW and N.
Digital tester
(+)Red
(-)Black
N
U
P
V
W
Digital tester
(+)Red
(-)Black
U
V
N
W
4.Indoor AC Fan Motor
Measure the resistance value of each winding by using the tester.
DA108X1C-23EZ
DA130M1C-31FZ
1.1Ω
(20℃)
Normal resistance value
(Several MΩ)
Normal resistance value
(Several MΩ)
Resistance Value
DA250S2C-30MT
0.95Ω
0.55Ω
(20℃)
(20℃)
61
DA150S1C-20FZ
0.95Ω
(20℃)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acp-18ch50aeliAcp-12ch35aeliAcp-22ch65aeli

Table of Contents