SPI JTAG Connector
Pin Pin Assignment
Pin Pin Assignment
1
3V_standby
2
Ground
3
CS
4
CK
5
SO
6
SI
7
HOLOD-
Chapter 2 Hardware Installation
Chapter 2
Battery Low
2
1
7
This jumper is used to simulate the signal status that indicates the external battery is low. By
setting to pins 1 and 2 to On, it sends a battery low signal to the module.
29
1 2
1-2 On: Battery low
1 2
1-2 Off: Normal
(default)
www.dfi.com