14.1. Error code output
NOTE:
The error code is output if the heater is fitted with a control element after
an error has occurred by the switch-on indicator/error code indicator
flashing. After 5 seconds of fast flashing, the error code will be output by
a sequence of long flash pulses, the number of flashes is shown in the
table below.
If the heater is fitted with a combination timer, an error message will
appear on the display of the timer after a fault occurs: If the control
element is used the error number is indicated by the indicator light
flashing:
F 00
Control unit error / incorrect data set / customer bus defective
F 01
No start (after 2 attempts to start) / no flame formation
F 02
Flame failure (repeated > 3)
F 03
Undervoltage or overvoltage
F 04
Premature flame recognition
F 05
Flame monitor (petrol heater) interrupt or short circuit
F 06
Temperature sensor interrupt or short circuit
F 07
Metering pump interrupt or pump short circuit
F 08
Fan motor interrupt or short circuit or overload or blocked
F 09
Glow plug interrupt or short circuit
F 10
Overheating: Resulting in permanent heater fault lock-out
F 11
Overheating sensor interrupt or short circuit
F 12
Heater lock-out
F 14
Overheating sensor incorrect position
F 15
Setpoint generator interrupt
Fault lock-out