To power the LCD from the external battery (cordless operation):
• Insert battery pack into inflator until an audible
click is heard (figure I). Make sure battery pack is
fully seated and fully latched into position.
Note: To remove battery, depress the battery
release button in the back of the battery pack and
pull battery pack out.
• Push the main power switch to the right (inflate
position) to power up the LCD (figure H).
WARNING:
Risk of Bursting. Do not leave unit
running unattended. Overinflation of tires and other
items could result in serious injury and property
damage.
QUICK START
WARNING:
Never leave inflator running unattended in this mode. In can burst car
tires and other items.
To use your inflator immediately you can do so without setting the automatic shut-off
feature.
• Push the main power switch to the right (inflate
position, figure H).
• To switch between the different units (PSI, BAR or
KPA) press - & + buttons together repeatedly until
the required units are displayed (figure J).
• Connect the universal valve adaptor and an
accessory, if required, to the item to be inflated,
making sure that the lever of the valve adaptor is in
the down position to lock it in place.
Note: Make sure that the universal valve adaptor is
correctly fitted to the item to be inflated.
• To start the inflator, press the power button on the
LCD (figure K).
• When the item is inflated as required or to stop the
inflator at any time press the power button on the
LCD.
Note: When the inflator is shut off, the pressure reading displayed will drop slightly from
the reading displayed while the inflator is running. This pressure reading with the inflator
off is correct.
• Remove the hose from the item and store it on the side of the unit.
• Turn the main power switch to the off (middle) position.
SETTING THE AUTOMATIC SHUT-OFF PRESSURE
Note: The LCD will only show inflation pressures when the inflator is being used.
• To switch between the different units (PSI, BAR or KPA) press - & + buttons together
repeatedly until the required units are displayed (figure J).
• To set shut off pressure, press and hold either + or – button until the display starts to
flash, then release.
• Press + or – button until the desired pressure is displayed.
• The display will flash 3 times and return to a reading of "0.0". This is normal.
• Connect the universal valve adaptor and accessories, if required, to the item to be
inflated, making sure that the lever of the valve adaptor is in the down position to lock
it in place.
• To start the inflator, press the power button on the LCD (figure K).
• When the item to be inflated has reached the preset value, the unit will automatically turn off.
Note: You may notice the actual pressure reading may drop after a couple of seconds,
this is normal.
• To stop the inflator at any time press the power button on the LCD (figure K).
• Remove the valve adaptor or accessory from the inflated item and the 12 Volt adapter
7/22/11