Appendix A. Troubleshooting
Procedure
6.
On the Connect tab, choose I do not know
the IP address of the welder.
7.
Click the Refresh List button.
8.
Select the welder and click Connect.
9.
Click Connection in the navigation tree.
10.
Select the welder and click Configure.
11.
Edit the Ethernet settings to those provided
by your IT department.
12.
Click OK.
13.
Unplug the Ethernet cable from the Welding
Power Source.
14.
Reconnect the Welding Power Source to the
plant network again.

Ethernet Settings Seem Valid but Still Cannot Connect

If you have checked the Ethernet settings, and they are valid, use the following information to verify
communications and physical connections:
Check the physical network connections to the computer and the power source. Check for a
solid green or yellow light near each Ethernet jack. If you see a light, the physical connections
are probably not the issue.
Cycle the power to the Welding Power Source (off then back on). The power source could still
have a residual network connection in its memory under some circumstances.
If you continue to have trouble connecting, verify the following:
Do you have multiple Ethernet adapters enabled? This could cause issues. Verify that the
Ethernet communications are going through a single adapter. To do this, temporarily disable
any additional adapters.
If you are using an Ethernet cable connection, try to temporarily disable any wireless
communication on the computer. This could help the computer to directly connect to the
Welding Power Source through the cable without interference.
If the computer is running some type of security software or firewall, this may block the IP
address of the Welding Power Source. Check with your local IT department.
A.2
Details
Only one IP address should appear.
TIP |
status light on the machine should begin to blink.
The system automatically takes you to the System
status section in Power Wave® Manager.
See page 4.3 for more details on the settings
available.
The Welding Power Source resets and accepts its new
network settings.
The new settings should take effect.
Power Wave® Manager User Manual
Cannot Connect to a Power Source
When you select the power source, the green
IM8002