These same connections are used
for Zones 7-12 on the second PZ6.
INSTALLATION TIP
Use the Color-code
overlay to ensure
correct ZPAD
punchdown
connections
NOTE: A maximum of six
ZPADS may be connected
to one Z630 PreAmp
Controller
© ELAN Home Systems 2002 • All rights reserved. 3/02
-
.
CONT
Z•PAD C C ONNECTIONS
There are six keypad punchdown connectors provided on the rear panel of the
PZ6 - one for each of the six zones in a dual Z•630 System. The six keypad
punchdown connectors are labeled Zone 1 thru Zone 6.
CONNECTING M M ORE T T HAN O O NE Z Z •PAD P P ER Z Z ONE
Two 22 or 24 AWG solid conductor wires can be punched down into each row
of the connector, making it easy to connect two Z•PADs per zone. If using more
than two Z•PADs in one zone, the keypad wires would need to be spliced to a
lead wire which would then be punched down to the connector.
Z•025 S S PEAKER R R ELAY/AB S S ENSING M M ODULE
When using Z•025 Speaker Relay/AB Sensing Modules in conjunction with
Z•PADs, the Zone punchdown connectors on the PZ6 provide the necessary
connections for the VC+ and VC- wires that enable Page and Doorbell override
control. Use two of the remaining conductors from the CAT-5 keypad wire run
(Orange for VC+ and White/Brown for VC-) to make this connection.