Download Print this page
DELTA DORE TYBOX 817 W RF Installation Instructions
DELTA DORE TYBOX 817 W RF Installation Instructions

DELTA DORE TYBOX 817 W RF Installation Instructions

1 and 2-channel wireless programmers with built-in thermostat

Advertisement

Quick Links

TYBOX 817- 827 W RF
1 and 2-channel wireless programmers
with built-in thermostat
Installation instructions
Delta Dore hereby declares that the equipment complies
with the essential requirements and other relevant provisions
of the R&TTE Directive 1999/5/EC.
The EC declaration of conformity for this equipment is available,
on request, from:
"Technical info" department
DELTA DORE - Bonnemain - 35270 Combourg (France)
Email: info.techniques@deltadore.com
Because of changes in standards and equipment, the characteristics given in the
text and the illustrations in this document are not binding unless confirmed.
3. Installing the transmitter
A
~1.50 m
B
Mini 20 cm
A
1
5. Associating the transmitter with the receiver
The transmitter and the receiver are associated when delivered.
You may however need to reassociate your products
(after removing wireless associations for instance).
... ... ...
1
2
> 3"
• These instructions apply to both TYBOX 817 WRF
and TYBOX 827 WRF.
• The hot water mode (
) is only available on the
TYBOX 827 WRF.
• Carefully read these instructions prior to
installation.
• The unit must be installed in compliance with
current standards.
• Always switch off the mains before installing
or servicing the unit.
• Do not attempt to repair the unit yourself; after-sales
service is available.
• Check that the fastenings are suitable for the
surface to which the unit will be mounted
(plasterboard, brick, etc.).
• The diagrams provided are simplified for greater
clarity.
Protection and other accessories required by
standards are not illustrated.
Standards and good practice must be complied
with. Connected or nearby units must not
generate excessive interference (Directive
2004/108/EC).
2. Connecting the RF 817 or RF 827 receiver
RF 817
Example 1: 230V powered output
L
N
CH
OFF
N
L
1
2
230V~
50-60 Hz
3A max. / 230V~
Example 2: Dry contact output
L
N
CH
OFF
N
L
1
2
230V~
50-60 Hz
3A max. / 230V~
B
1
2
3
6
7
1. Installing the RF 817 or 827 receiver
2
HW
CH
OFF
OFF
N
L
1
2
230V~
50-60 Hz
3A max.
Cons. 11 VA
P = 1.2 W
(230V~)
RF 827
With a 3-port mid-position valve
CH
ON
3
4
L
N
CH
N
L
ON
3
4
230V~
50-60 Hz
2
3
3
4
> 5"
4
8
9
3
1
RF 817
CH
OFF
N
L
1
2
3
230V~
50-60 Hz
3A max. / 230V~
Cons. 11 VA
P = 1.2 W
RF 827
HW
CH
HW
CH
HW
ON
ON
OFF
OFF
ON
3
4
N
L
1
2
3
230V~
50-60 Hz
3A max.
Cons. 11 VA
(230V~)
P = 1.2 W
With 2 spring-return valves
with auxiliary switches
L
N
GR O
BL W
Pump or
CYL. STAT
boiler
1
2
C
HW
CH
HW
CH
OFF
OFF
ON
ON
1
2
3
4
3A max. (230V~)
4. Date / time
4
5
6. Compatible home automation options
You can associate your programmer with the
following options:
transmitter
associated
Opening
detector
5
Wireless
outdoor
sensor
10
OK
4
CH
ON
4
6
CH
ON
4
5
Pump or
CYL. STAT
1
2
boiler
C
HW
CH
HW
CH
OFF
OFF
ON
ON
N
L
1
2
3
4
230V~
50-60 Hz
3A max. (230V~)
2
DD.MM.YY
PM
1
3
11.59
(23.59)
AM
12.00
(00.00)
R
: back to previous
setting
4
Type of
Resulting function
"Waste prevention" function
Heating switches to Frost Protection
mode when a window is opened
(temperature set in
mode).
Indication of outside
temperature by consulting the
i
information menu (
button).
For information about associating and
using home automation products,
contact:
"Technical info" department
DELTA DORE - Bonnemain
35270 Combourg (France)
Email: info.techniques@deltadore.com

Advertisement

loading

Summary of Contents for DELTA DORE TYBOX 817 W RF

  • Page 1 RF 827 Example 1: 230V powered output With a 3-port mid-position valve With 2 spring-return valves Delta Dore hereby declares that the equipment complies with auxiliary switches with the essential requirements and other relevant provisions of the R&TTE Directive 1999/5/EC.
  • Page 2 7. Basic configurations (menu 1) HH:MM HH:MM > 5" Modification of programme 12-hour clock (default) Setting from 12:00 to 00:00 (default value: 07:00AM) and temperature settings ONCE Time display User (from 5 °C to 30 °C) programme selection 24-hour clock modification start time authorised (default)

This manual is also suitable for:

Tybox 827 w rfTybox 817 wrfTybox 827 wrf