HAZARD
Risk of injection
WHAT COULD HAPPEN
Spray guns operate at pressures and velocities
high enough to penetrate human and animal
flesh, which could result in amputation or other
serious injury. ! See a physician immediately!
Air Inlet
Maximum Air Pressure
Recommended Operating Air Pressure
Cup
removal of any part of gun or
attached components, shut off
compressor, release pressure
by depressing trigger, and
disconnect power source.
NEVER assume system pres-
sure is zero!
UNCLOG (BACK FLUSH) SPRAY
GUN BY SQUEEZING TRIGGER
WHILE HOLDING FINGER IN
FRONT OF FLUID NOZZLE.
to viscosity of material used.
Maximum working pressure of
gun is 100 psi. DO NOT EXCEED
PRESSURE LIMIT OF GUN OR
ANY OTHER COMPONENT IN
SYSTEM!
D28996
SPECIFICATIONS
GENERAL INFORMATION
Before
disassembly or
OPERATION
DO NOT
ATTEMPT TO
Pressure may
vary according
HOW TO PREVENT IT
Never place hands in front of nozzle.
Direct spray away from self and others.
1/4 NPS
100 psi.
45 psi.
600 cc (20.29 oz)
EXPLOSIVE ATMOSPHERE,
WORK ONLY IN WELL-
VENTILATED AREAS.
RECOMMENDED TO PREVENT
INHALATION OF TOXIC MATE-
RIAL.
certain that all connections and
fittings are secure. Check hose
and all connections for a weak
or worn condition that could
render system unsafe. All re-
placement components such as
hose or fittings must have a
working pressure equal to or
greater than system pressure.
4- ENG
TO AVOID
CREATING AN
USE OF A FACE
MASK IS
Prior to daily
operation, make