Factory
service/customer menu 3
Table water may not be set, only existent in software
versions 3.1.1 and 3..1 (was not further pursued and
developed)
Water tank is automatically detected by nonexistent
intake valve (no = water tank machine)
(See chapter boiler
Drain of drip tray must be correctly adjusted manually.
Factory
service/customer menu 4
It only makes sense to adjust the 2. level if milk is
available.
Tablet insert ("Handrein") must be set manually for more
than portioners, for up to two portioners manual insert
coffee (HandKaff)
Accounting must be set manually
(MDB or serial connection)
Factory
service/customer menu 5
Grounds disposal through counter must be correctly set
manually. (default = internal)
Decaf must be set manually.
Safety queries follow acceptance.
WMF presto Service manual edition 08/2007
Must be set to "no" (not applicable for version >03.0.01)
Water tank existent?
Drip drain existent? (changes cleaning and descaling )
water system)
Beverages configured on levels
Manual insert for coffee and cleaning or cleaning only
Accounting via accessory device via MDB or serial connection
Operating mode grounds container: external = grounds disposal
through counter
Preselect-button for decaf brewing instead of steam button
(from 03.0.01)
Accept
WMF presto Service Manual
See chapter Boiler water systems
See chapter Boiler water systems
See chapter dripping-pan
See chapter dripping-pan
in the training manual
in the training manual
Part 2 Engineering
Part 2 Engineering
See user manual and additional
See user manual and additional
user manual for accounting.
user manual for accounting.
See user manual
See user manual
11