Electrical Safety; Using An Extension Cable - DeWalt D28111 Instruction Manual

Angle grinder
Hide thumbs Also See for D28111:
Table of Contents

Advertisement

D28113(K)/D28130/D28132C/D28134/D28135(K)/D28141 -
KEYLESS GUARD
The keyless guard allows for quick adjustment during
the application to enhance application versatility.
D28113(K)/D28130/D28132C/D28134/D28135(K)/D28141 -
DUST EJECTION SYSTEM
The dust ejection system prevents dust pile-up
around the guard and motor inlet, and minimises the
amount of dust entering the motor housing.

Electrical safety

The electric motor has been designed for one
voltage only. Always check that the power supply
corresponds to the voltage on the rating plate.
Your D
WALT tool is double insulated in
E
accordance with EN 60745; therefore no
earth wire is required.
WARNING: 115 V units have to
be operated via a fail-safe isolating
transformer with an earth screen between
the primary and secondary winding.
If the supply cord is damaged, it must be replaced
by a specially prepared cord available through the
D
WALT service organization.
E
Mains plug replacement
(U.K. & Ireland only)
• Should your mains plug need replacing and you
are competent to do this, proceed as instructed
below. If you are in doubt, contact an authorized
D
WALT repair agent or a qualifi ed electrician.
E
• Disconnect the plug from the supply.
• Cut off the plug and dispose of it safely; a plug
with bared copper conductors is dangerous if
engaged in a live socket outlet.
• Only fi t 13 Amperes BS1363A approved plugs
fi tted with the correctly rated fuse (1).
• The cable wire colours, or a letter, will be marked
at the connection points of most good quality
plugs. Attach the wires to their respective points
in the plug (see below). Brown is for Live (L) (2)
and Blue is for Neutral (N) (4).
• Before replacing the top cover of the mains plug
ensure that the cable restraint (3) is holding the
outer sheath of the cable fi rmly and that the two
leads are correctly fi xed at the terminal screws.
4
3
WARNING: Never use a light socket.
Never connect the live (L) or neutral (N)
wires to the earth pin marked E or
For 115 V units with a power rating exceeding 1500 W,
we recommend to fi t a plug to BS4343 standard.

Using an extension cable

If an extension cable is required, use an approved
extension cable suitable for the power input of this
tool (see technical data). The minimum conductor
size is 1.5 mm
2
.
When using a cable reel, always unwind the cable
completely.
Also refer to the table below.
2
Conductor size (mm
)
Cable rating (Amperes)
0.75
6
1.00
10
1.50
15
2.50
20
4.00
25
Cable length (m)
7.5
15
Voltage
Amperes
Cable rating (Amperes)
115
0 - 2.0
6
2.1 - 3.4
6
3.5 - 5.0
6
5.1 - 7.0
10
10
7.1 - 12.0
15
15
12.1 - 20.0
20
20
230
0 - 2.0
6
2.1 - 3.4
6
3.5 - 5.0
6
5.1 - 7.0
10
10
7.1 - 12.0
15
15
12.1 - 20.0
20
20
E N G L I S H
1
2
.
25
30
45
60
6
6
6
6
10
6
6
6
15
15
6
10
15
20
20
15
20
20
25
20
25
25
-
25
-
-
-
6
6
6
6
6
6
6
6
6
6
6
6
6
10
15
10
10
15
15
15
15
20
20
20
20
25
-