Utp Cable Wiring Standards - Kingston Technology KNS500/WG User Manual

Fast etherx 5-port & 8-port 10/100tx workgroup fast ethernet switch
Table of Contents

Advertisement

12

UTP Cable Wiring Standards

There are two governmental agencies: the Electronic Industry Association
(EIA) and the Telecommunications Industry Association (TIA), which set the
standard for all cable wiring requirements for commercial buildings.
With the advent of 100Mb/s networking products, it is best to use higher
quality CAT 5 cables like Belden or Helix as well as CAT 5-compliant patch
panels, patch cables, and connectors while following the EIA/TIA wiring
standards. 100
Refer to the illustrations below for 4-pair wiring using either T568A (Fig. B-1)
or T568B (Fig. B-2) wiring standards. Both T568A and T568B wiring is
compatible with 10BASE-T and 100BASE-TX and require no special
configurations, but for premise wiring, stick to one wiring standard. Mixing
T568A and T568B wiring schemes may cause or lead to potential problems.
Pair 3 Pair 1 Pair 4
Fig. B-1 4-Pair T568A Wiring
T568A
Pairs
Pin 1
Pair 3
Pin 2
Pair 3
Pin 3
Pair 2
Pin 4
Pair 1
Pin 5
Pair 1
Pin 6
Pair 2
Pin 7
Pair 4
Pin 8
Pair 4
Table. B-4 4-Pair T568A Wiring
Kingston Technology Company
UTP CAT 5 type cables use 4-pair UTP wiring.
Pair 2
1 2 3 4 5 6 7 8
T568A
Strand
Solid
Blue
White/Green
Orange
Green/White
Black
White/Orange
Red
Blue/White
Green
White/Blue
Yellow
Orange/White
Brown
White/Brown
White
Brown/White
Appendix B
Pair 2 Pair 1 Pair 4
1 2 3 4 5 6 7 8
Fig. B-2 4-Pair T568B Wiring
T568B
Pairs
Pin 1
Pair 2
Pin 2
Pair 2
Pin 3
Pair 3
Pin 4
Pair 1
Pin 5
Pair 1
Pin 6
Pair 3
Pin 7
Pair 4
Pin 8
Pair 4
Table B-5 4-Pair T568B Wiring
KNS800/WG User's Guide – Rev.B01
Cabling Guidelines
Pair 3
T568B
Strand
Solid
Black
White/Orange
Yellow
Orange/White
Blue
White/Green
Red
Blue/White
Green
White/Blue
Orange
Green/White
Brown
White/Brown
White
Brown/White