Cheapernet, 10BASE5 thick Ethernet connection, 10BASE-T or FOIRL (Fiber Optic Inter Repeater Link) segment using a proper external transceiver. All models include: a cascade switch on the last UTP port (Port 8 or Port 16) which supports both straight-through or crossover cable types by simply moving the switch on the front panel.
• Utilization and Collision LEDs displays network traffic and number of collisions in five LED percentage levels • Cascade Switch on last UTP port (Port 8 or 16) to support crossover or straight-through cable wiring types • Automatic partition and reconnection •...
Collision Handling The EtheRx hub will detect and respond to collision conditions as outlined in the IEEE 802.3 specifications. Kingston Technology Company EtheRx User’s Guide - Rev. B00...
UTP port after that port’s transmitter is inactive for a range of 8ms to 17ms. These pulses are sent to confirm that a valid connection exists between each UTP port on the hub and its attached device. EtheRx User’s Guide - Rev. B00 Kingston Technology Company...
“Stack-In” and “Stack-Out” port for stacking up to five (5) SE hubs in any combination of 8-Port and 16-Port models. Refer to the section, “Stacking EtheRx SE Hubs” on page 13 for additional information. Kingston Technology Company Stackable Hub KNE8TP/SE...
LED will display red to show the port has been partitioned. Upon receipt of good packets, the LED will automatically change from red to green indicating that the port is functioning properly. EtheRx User’s Guide - Rev. B00 LED 2 LED 3 LED 4 LED 5 Kingston Technology Company...
Appendix B for cabling guidelines. Cascade Switch The Cascade Switch provides cable wiring flexibility on the last UTP Port (i.e., Port 8 or Port 16) for connecting to a workstation or cascading to another hub. By default, the last UTP port is set to “Crossover” (left side) as a standard, internally-crossed port, or MDI-X port.
Position Config another Hub Port (MDI-X) MDI-X Use Crossover cable Use Straight-through cable Table 1-5 Cable Switch functions EtheRx User’s Guide - Rev. B00 For Connection to a Network Adapter (MDI) Use Straight-through cable Use Crossover cable Kingston Technology Company...
Since crossover function is implemented on all UTP MDI-X ports, a straight-through UTP cable should be used. Note: Port 8 and Port 16 support both cable types using the Cable Switch. Refer to Appendix B for details on RJ-45 pin assignments and cable specifications.
Ethernet hub. Since a Crossover function is implemented on all ports (except the last UTP port which uses a Cable Switch to support both cable types), a Straight-Through UTP cable should be used. The physical network connection is illustrated in Figure 3-1.
BNC port, AUI port (16-Port models only), or one of the UTP ports. To cascade to another hub, use the last UTP port which has a cascade switch to support either straight through or crossover cable types. Figure 3-3 below is an example of horizontal cascading using the KNE16TP/WG under the Ethernet 5-4-3 rule.
"Appendix B Cable Connections" for reference in creating a twisted-pair cable. Fig. A-1 RJ-45 Connector Pin Numbers Pin Number Table A-2 UTP Pin Assignments EtheRx User’s Guide - Rev. B00 Function Transmit Data + Transmit Data - Receive Data + Not Used Receive Data - Not Used Kingston Technology Company...
10BASE5 thick coaxial, 10BASE-T twisted pair, and Fiber Optic Inter-Repeater Link (FOIRL) using an external transceiver. Refer to the Figure below. Fig. A-3 AUI Connector on Rear Panel Pin Number Table A-4 AUI Pin Assignments Kingston Technology Company 10BASE2 thin Function Collision Shield Collision + Transmit +...
FCC Class A, CE CISPR A EMC Standards: EN55022, IEC801-2, IEC801-3, IEC801-4 Low Voltage Directive: EN60950 Optional Accessories: AC Power Transformer KNA110PS (U.S.) or KNA220PS (Europe) EtheRx User’s Guide - Rev. B00 European version: 230VAC, 50Hz 12VAC / 1.5A Kingston Technology Company...
Page 26
FCC Class A, CE CISPR A EMC Standards: EN55022, IEC801-2, IEC801-3, IEC801-4 Low Voltage Directive: EN60950 Optional Accessories: AC Power Transformer: KNA110PS (U.S.) or KNA220PS (Europe) Kingston Technology Company European version: 230VAC, 50Hz 12VAC / 1.5A EtheRx User’s Guide - Rev. B00...
The illustrations below detail the measurements and mounting holes and rubber feet locations. They are drawn to scale, although not actual size. Fig. D-1 Mounting Template specifications EtheRx User’s Guide - Rev. B00 Kingston Technology Company...
Appendix E Product Warranties and Notices Limited Warranty KINGSTON TECHNOLOGY COMPANY ("Kingston") warrants that this product is free from defects in material and workmanship. Subject to the conditions and limitations set forth below, Kingston will, at its option, either repair or replace any part of this product which proves defective by reason of improper workmanship or materials.
Page 30
CE Notice The official CE symbol indicates compliance of this Kingston Technology product to the EMC directive of the European Community. The CE symbol found here or elsewhere indicates that this Kingston product meets or exceeds...
Internet: Visit Kingston’s Web site at http://www.kingston.com For Product Information: sales@kingston.com For Technical Support: tech_support@kingston.com RAMfax: Automatic Faxback System (U.S. and Canada) (800) 435-0056 or (714) 435-2677 Revision History EtheRx User’s Guide - Rev. B00 ™ GO KINGSTON Kingston Technology Company...
LEDs for AUI and BNC ports on front panel. For 16-Port model only. Same as above. For both 8-Port and 16- Port models. Added CE logo and Part No. to title page. Combined Workgroup and SE hubs. Kingston Technology Company EtheRx User’s Guide - Rev. B00...
Need help?
Do you have a question about the KNE16SE and is the answer not in the manual?
Questions and answers