Kingston Technology KNE16SE User Manual

Kingston etherx 10base-t workgroup and stackable ethernet hubs user's guide

Advertisement

Kingston Technology
EtheRx 10BASE-T WorkGroup
and Stackable Ethernet Hubs
User's Guide
Models:
KNE8TP/WG
KNE8TP/SE
KNE16TP/WG
KNE16TP/SE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KNE16SE and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kingston Technology KNE16SE

  • Page 1 Kingston Technology EtheRx 10BASE-T WorkGroup and Stackable Ethernet Hubs User’s Guide Models: KNE8TP/WG KNE8TP/SE KNE16TP/WG KNE16TP/SE...
  • Page 3 Kingston’s Technology’s EtheRx 10BASE-T WorkGroup and Stackable 8-Port and 16-Port Ethernet Hubs User’s Guide Part No. 4460001-001.B00 Kingston Technology Company 17600 Newhope Fountain Valley, CA 92708 (714) 435-2600 EtheRx User’s Guide - Rev. B00 Kingston Technology Company...
  • Page 5: Table Of Contents

    Front Panel...6 Power LED...6 Stacking Ports (SE models only)...6 Utilization and Collision LEDs ...7 AUI LED ...7 BNC LED ...7 8 or 16 UTP Port LEDs ...8 Cascade Switch ...8 EtheRx User’s Guide - Rev. B00 ONTENTS Kingston Technology Company...
  • Page 6 Cable Type ... 17 Cable Wiring Standards ... 18 Appendix C Specifications... 19 Appendix D Mounting Templates ... 21 Appendix E Product Warranties and Notices ... 22 How to Reach Kingston ... 25 Kingston Technology Company EtheRx User’s Guide - Rev. B00...
  • Page 7: Introduction

    Cheapernet, 10BASE5 thick Ethernet connection, 10BASE-T or FOIRL (Fiber Optic Inter Repeater Link) segment using a proper external transceiver. All models include: a cascade switch on the last UTP port (Port 8 or Port 16) which supports both straight-through or crossover cable types by simply moving the switch on the front panel.
  • Page 8: Model Types

    KNE16TP/WG COLL % KNE16TP/WG 16-Port WorkGroup Hub STACK IN STACK OUT UTIL % ACTIVITY / PARTITION LINK / ACTIVITY / PARTITION COLL % KNE16TP/SE 16-Port Stackable Hub Kingston Technology Company CASCADE Stackable Hub KNE8TP/SE CASCADE CASCADE Stackable Hub CASCADE KNE16TP/SE...
  • Page 9: Special Features

    • Utilization and Collision LEDs displays network traffic and number of collisions in five LED percentage levels • Cascade Switch on last UTP port (Port 8 or 16) to support crossover or straight-through cable wiring types • Automatic partition and reconnection •...
  • Page 10: Design Features

    Collision Handling The EtheRx hub will detect and respond to collision conditions as outlined in the IEEE 802.3 specifications. Kingston Technology Company EtheRx User’s Guide - Rev. B00...
  • Page 11: Automatic Partitioning/Reconnection

    UTP port after that port’s transmitter is inactive for a range of 8ms to 17ms. These pulses are sent to confirm that a valid connection exists between each UTP port on the hub and its attached device. EtheRx User’s Guide - Rev. B00 Kingston Technology Company...
  • Page 12: Hardware Installation

    “Stack-In” and “Stack-Out” port for stacking up to five (5) SE hubs in any combination of 8-Port and 16-Port models. Refer to the section, “Stacking EtheRx SE Hubs” on page 13 for additional information. Kingston Technology Company Stackable Hub KNE8TP/SE...
  • Page 13: Utilization And Collision Leds

    LED will display red to show the port has been partitioned. Upon receipt of good packets, the LED will automatically change from red to green indicating that the port is functioning properly. EtheRx User’s Guide - Rev. B00 LED 2 LED 3 LED 4 LED 5 Kingston Technology Company...
  • Page 14: Or 16 Utp Port Leds

    Appendix B for cabling guidelines. Cascade Switch The Cascade Switch provides cable wiring flexibility on the last UTP Port (i.e., Port 8 or Port 16) for connecting to a workstation or cascading to another hub. By default, the last UTP port is set to “Crossover” (left side) as a standard, internally-crossed port, or MDI-X port.
  • Page 15: Using A Crossover Cable

    Position Config another Hub Port (MDI-X) MDI-X Use Crossover cable Use Straight-through cable Table 1-5 Cable Switch functions EtheRx User’s Guide - Rev. B00 For Connection to a Network Adapter (MDI) Use Straight-through cable Use Crossover cable Kingston Technology Company...
  • Page 16: Rear Panel

    Since crossover function is implemented on all UTP MDI-X ports, a straight-through UTP cable should be used. Note: Port 8 and Port 16 support both cable types using the Cable Switch. Refer to Appendix B for details on RJ-45 pin assignments and cable specifications.
  • Page 17: Network Configurations

    Ethernet hub. Since a Crossover function is implemented on all ports (except the last UTP port which uses a Cable Switch to support both cable types), a Straight-Through UTP cable should be used. The physical network connection is illustrated in Figure 3-1.
  • Page 18: Linear Bus Network

    BNC port, AUI port (16-Port models only), or one of the UTP ports. To cascade to another hub, use the last UTP port which has a cascade switch to support either straight through or crossover cable types. Figure 3-3 below is an example of horizontal cascading using the KNE16TP/WG under the Ethernet 5-4-3 rule.
  • Page 19: Stacking Etherx Se Hubs

    LINK / ACTIVITY / PARTITION COLL % Fig. 3-4 Stackable SE Hub Configuration EtheRx User’s Guide - Rev. B00 Stackable Hub KNE8TP/SE CASCADE Stackable Hub KNE8TP/SE CASCADE Stackable Hub KNE8TP/SE CASCADE Stackable Hub KNE8TP/SE CASCADE Stackable Hub KNE8TP/SE CASCADE Kingston Technology Company...
  • Page 20: Appendices

    Appendices Kingston Technology Company EtheRx User’s Guide - Rev. B00...
  • Page 21: Appendix A Pin Assignments

    "Appendix B Cable Connections" for reference in creating a twisted-pair cable. Fig. A-1 RJ-45 Connector Pin Numbers Pin Number Table A-2 UTP Pin Assignments EtheRx User’s Guide - Rev. B00 Function Transmit Data + Transmit Data - Receive Data + Not Used Receive Data - Not Used Kingston Technology Company...
  • Page 22: Aui Pin Assignments (16-Port Models Only)

    10BASE5 thick coaxial, 10BASE-T twisted pair, and Fiber Optic Inter-Repeater Link (FOIRL) using an external transceiver. Refer to the Figure below. Fig. A-3 AUI Connector on Rear Panel Pin Number Table A-4 AUI Pin Assignments Kingston Technology Company 10BASE2 thin Function Collision Shield Collision + Transmit +...
  • Page 23: Appendix B Cabling Guidelines

    Pin Number Pin Number 1 (TRX +) 3 (RCV +) 2 (TRX -) 6 (RCV -) 3 (RCV +) 1 (TRX +) 6 (RCV -) 2 (TRX -) 4, 5, 7, 8 Not Used Table B-3. Crossover Wiring Kingston Technology Company...
  • Page 24: Cable Wiring Standards

    Pair 2 Pair 1 Pair 4 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 T568B T568A Fig. B-6 4-Pair T568B Wiring Fig. B-5 4-Pair T568A Wiring Kingston Technology Company EtheRx User’s Guide - Rev. B00...
  • Page 25: Appendix C Specifications

    FCC Class A, CE CISPR A EMC Standards: EN55022, IEC801-2, IEC801-3, IEC801-4 Low Voltage Directive: EN60950 Optional Accessories: AC Power Transformer KNA110PS (U.S.) or KNA220PS (Europe) EtheRx User’s Guide - Rev. B00 European version: 230VAC, 50Hz 12VAC / 1.5A Kingston Technology Company...
  • Page 26 FCC Class A, CE CISPR A EMC Standards: EN55022, IEC801-2, IEC801-3, IEC801-4 Low Voltage Directive: EN60950 Optional Accessories: AC Power Transformer: KNA110PS (U.S.) or KNA220PS (Europe) Kingston Technology Company European version: 230VAC, 50Hz 12VAC / 1.5A EtheRx User’s Guide - Rev. B00...
  • Page 27: Appendix D Mounting Templates

    The illustrations below detail the measurements and mounting holes and rubber feet locations. They are drawn to scale, although not actual size. Fig. D-1 Mounting Template specifications EtheRx User’s Guide - Rev. B00 Kingston Technology Company...
  • Page 28: Appendix E Product Warranties And Notices

    Appendix E Product Warranties and Notices Limited Warranty KINGSTON TECHNOLOGY COMPANY ("Kingston") warrants that this product is free from defects in material and workmanship. Subject to the conditions and limitations set forth below, Kingston will, at its option, either repair or replace any part of this product which proves defective by reason of improper workmanship or materials.
  • Page 29: Free Technical Support

    Copyright © 1997 Kingston Technology Company. All rights reserved. Printed in the U.S.A. Kingston Technology and the Kingston logo are trademarks of Kingston Technology Company. Mac and the Mac OS logo are trademarks of Apple Computer, Inc., used under license. All other trademarks are properties of their respective companies.
  • Page 30 CE Notice The official CE symbol indicates compliance of this Kingston Technology product to the EMC directive of the European Community. The CE symbol found here or elsewhere indicates that this Kingston product meets or exceeds...
  • Page 31: How To Reach Kingston

    Internet: Visit Kingston’s Web site at http://www.kingston.com For Product Information: sales@kingston.com For Technical Support: tech_support@kingston.com RAMfax: Automatic Faxback System (U.S. and Canada) (800) 435-0056 or (714) 435-2677 Revision History EtheRx User’s Guide - Rev. B00 ™ GO KINGSTON Kingston Technology Company...
  • Page 32: Revision Level

    LEDs for AUI and BNC ports on front panel. For 16-Port model only. Same as above. For both 8-Port and 16- Port models. Added CE logo and Part No. to title page. Combined Workgroup and SE hubs. Kingston Technology Company EtheRx User’s Guide - Rev. B00...

Table of Contents