Summary of Contents for Kingston Technology KND1610TX

  • Page 1 INGSTON ECHNOLOGY TACKABLE 8-PORT, 16-PORT, & 24-PORT 10/100TX OUNTABLE DUAL SPEED SER’S UIDE S: KND810TX ODEL KND1610TX KND2410TX...
  • Page 3 Fast EtheRx Stackable 8-Port, 16-Port, & 24-Port 10/100TX Rack-Mountable Dual Speed Hubs User’s Guide Part No. 4460064-001.A01 Kingston Technology Company 17600 Newhope Fountain Valley, CA 92708 (714) 435-2600 Important Safety Instructions KND2410TX User’s Guide - Rev. A01 Kingston Technology Company...
  • Page 4 Netzspannung sollte Händler oder Energieversorgungsunternehmen zu rate gezogen werden. 6. Nicht versuchen das Produkt selbst zu reparieren. In allen Produkten existieren gefährliche elektrische Spannugen. Nicht das Gehäuse öffnen. Table Of Contents Kingston Technology Company KND2410TX User’s Guide - Rev. A01...
  • Page 5: Table Of Contents

    AC Power Connector ..........6 Fuse..............6 Fan Unit(s) ............6 Stack-In / Stack-Out Ports ........7 Speed-Setting Dip Switches........8 Appendices..................9 Appendix A Pin Assignments ........10 UTP Port Pin Assignments........10 Appendix B Cabling Guidelines ........11 KND2410TX User’s Guide - Rev. A01 Kingston Technology Company...
  • Page 6 Commonly Asked Questions..... 15 Appendix E Warranties and Notices......16 Limited Warranty Statement ......17 Duration of Warranty......... 17 Free Technical Support........18 Disclaimers ............18 F.C.C. Certification..........19 CE Notice............19 Kingston Technology Company KND2410TX User’s Guide - Rev. A01...
  • Page 7: Introduction

    UTP port on the hub to support both crossover and straight-through cabling. By default port 7 & 8 (KND810TX & KND1610TX) or port 23 & 24 (KND2410TX) are set for auto-negotiation but can be manually configured for either 10Mbps or 100Mbps operation, using the dip switches located on the back of the unit.
  • Page 8: Special Features

    If any of the items are missing or damaged, please contact your Kingston dealer for a replacement. Be sure the items you receive are genuine Kingston Technology products. If the Kingston name and logo are not on the front panel of the unit, it’s not a genuine Kingston product.
  • Page 9: Design Features

    If the error conditions have been corrected or a good data packet is received or transmitted without a collision, the hub will automatically reconnect that port to the network. KND2410TX User’s Guide - Rev. A01 Kingston Technology Company...
  • Page 10: Hardware Installation

    A steady green light indicates that a good link has been established. A flashing green light indicates that data is being received. If the Link LED does not display a steady green link light, please check the following: Kingston Technology Company KND2410TX User’s Guide - Rev. A01...
  • Page 11: 10/100Tx Utp Ports

    The eight (8), sixteen (16), and twenty-four (24) 10/100TX UTP ports auto- negotiate both 10BASE-T and 100BASE-TX connections. The speed settings for ports 7 & 8 (on the KND810TX & KND1610TX models) and ports 23 & 24 (on the KND2410TX model) can also be manually configured to operate at 10Mbps or 100Mbps using the dip switches located on the back of the unit (see Speed-Setting Dip Switches in the Rear Panel section).
  • Page 12: Rear Panel

    Both fuses are rated 250V/2A max. Fan Unit(s) The Fast EtheRx dual-speed hubs use independent cooling fans for optimum air- flow to safeguard the unit from unnecessary heat exposure. Kingston Technology Company KND2410TX User’s Guide - Rev. A01...
  • Page 13: Stack-In / Stack-Out Ports

    The Fast EtheRx stackable hubs use stacking ports located on the back of the unit to stack up to a maximum of four hubs, using any combination of the KND810TX, KND1610TX, and KND2410TX models. Follow the directions below on stacking these hubs together: Power down the Fast EtheRx hub(s).
  • Page 14: Speed-Setting Dip Switches

    Speed-Setting Dip Switches The dip switches located on the back of the unit can be used to manually configure ports 7 & 8 (KND810TX & KND1610TX) or port 23 & 24 (KND2410TX) to operate at 10Mbps, 100Mbps, or Auto-negotiation (default).
  • Page 15: Appendices

    Appendices Appendices KND2410TX User’s Guide - Rev. A01 Kingston Technology Company...
  • Page 16: Appendix A Pin Assignments

    Not Used Transmit Data - Receive Data - Not Used Not Used Table A-1 UTP Pin Assignments (NOTE: For further details, refer to Notes on MDI & MDI-X on page 5) Kingston Technology Company KND2410TX User’s Guide - Rev. A01...
  • Page 17: Appendix B Cabling Guidelines

    6 (RCV-) 6 (RCV-) 6 (RCV-) 2 (TRX-) 4, 5, 7, 8 Not Used 4, 5, 7, 8 Not Used Table B-2. Straight-Through Wiring Table B-3. Cross-Over Wiring UTP Cable Wiring Standards KND2410TX User’s Guide - Rev. A01 Kingston Technology Company...
  • Page 18: Utp Cable Rating Codes

    Table B-5 4-Pair T568B Wiring UTP Cable Rating Codes UTP cables meet different UL-NEC requirements based on cable-jacket quality. Below is an explanation of the rating codes for each cable type. Kingston Technology Company KND2410TX User’s Guide - Rev. A01...
  • Page 19: Appendix C Specifications

    NEAR-END CROSSTALK (NEXT) – In wires packed together within a cable, the signals generated at one end of the link can flush out the weaker signals coming back from the recipient. Appendix C Specifications Fast EtheRx KND810TX, KND1610TX, KND2410TX KND2410TX User’s Guide - Rev. A01 Kingston Technology Company...
  • Page 20 -20°C to 60°C (-4°F to 140°F) Relative Humidity 10% to 90% non-condensing Electrical: Input Voltage: 100VAC-240VAC, 50/60Hz, auto-sensing internal power supply Output DC Voltage: KND810TX / KND1610TX: 5 Vdc / 6A KND2410TX: 5 Vdc / 11A KND810TX KND1610TX KND2410TX Power Consumption: 11.05 Watts max.
  • Page 21: Appendix D Commonly Asked Questions

    100 MHz by TSB-36 and TSB-40. The cable grades are categorized as follows: • Category 3: up to 16 MHz • Category 4: up to 20 MHz. • Category 5: up to 100 MHz. KND2410TX User’s Guide - Rev. A01 Kingston Technology Company...
  • Page 22: Appendix E Warranties And Notices

    Although only two pairs are used in the standard four-pair CAT 5 UTP cable, it is not recommended because it exceeds the specifications outlined by IEEE 802.3u. Appendix E Warranties and Notices Kingston Technology Company KND2410TX User’s Guide - Rev. A01...
  • Page 23: Limited Warranty Statement

    Appendix E Warranties and Notices Limited Warranty Statement KINGSTON TECHNOLOGY COMPANY ("Kingston") warrants that this product is free from defects in material and workmanship. Subject to the conditions and limitations set forth below, Kingston will, at its option, either repair or replace any part of this product which proves defective by reason of improper workmanship or materials.
  • Page 24: Appendix E Warranties And Notices

    Kingston product, even if Kingston has been advised of the possibility of such damages. Copyright © 1997 Kingston Technology Company. All rights reserved. Printed in Taiwan. Kingston Technology and the Kingston logo are trademarks of Kingston Technology Company. Kingston Technology Company KND2410TX User’s Guide - Rev. A01...
  • Page 25: F.c.c. Certification

    CE Notice The official CE symbol indicates compliance of this Kingston Technology product to the EMC directive of the European Community. The CE symbol indicates that this Kingston product meets or exceeds the following standards: EN50081-1 “Electromagnetic Compatibility-generic emissions standard”...

This manual is also suitable for:

Knd810txKnd2410tx

Table of Contents