Disassembly and Assembly Procedures

Disassembly Process of Indoor Unit
Operating Procedures / Photos
Disassemble Front Panel and
Pull open the front panel, unscrew the screw
fixing the receiving window, remove the guard
board, pull out the connecting terminal,unscrew
the fixing screws on the elextric box top cover,
remove the top cover,then pull out the panel alone
the fixing groove on front case.
(refer to Fig.7-1)
Disassemble Filter
Pull the filter upward a little and then push it
inward to remove the filter.
(refer to Fig.7-2)
Disassemble Guide Louver
Manually bend the guide louver to loosen the
clasp on it and then remove the guide louver.
(refer to Fig.7-3)
groove
panel
guard board
Filter
Guide Louver
screw
elextric box
connection
terminal
top cover
Fig.7-1
Fig.7-2
clasp
Fig.7-3