Installing The Optional Wall/Counter Mount - Honeywell MS7120 Orbit Manual

Hide thumbs Also See for MS7120 Orbit:
Table of Contents

Advertisement

I
NSTALLING THE
Kit #45-45619 contains:
a.
Locking Plate
[
50-50302]
MLPN
b.
Base Cover
[
50-50301]
MLPN
c.
Wood Screw, #7 x 1.00"
[
18-18013]
MLPN
d.
Flathead Screw, M3 x 8 mm
[
18-18004]
MLPN
1.
Drill mounting holes
Note the position Orbit will rest (fig. 2).
Use the dimensions provided in
figure 2 or the locking plate
[
50-50302] as a template to drill
MLPN
three #39 pilot holes.
2.
Mount locking plate to wall/counter
Secure the locking plate [
the counter or wall with the three #7 x 1.00" wood
screws [
MLPN
3.
Attach the base plate to Orbit
Secure the base cover [
using the four M3 x 8 mm screws [
4.
Mount Orbit to locking plate
Hold Orbit 90° clockwise from the desired position then lower it over
the locking plate until it sits flush to the countertop. Twist Orbit counter
clockwise 90°, as shown in figure 5, to lock unit in place.