Da-Lite Cosmopolitan Electrol Instruction Book page 6

For sizes up to 9' x 12'
Hide thumbs Also See for Cosmopolitan Electrol:
Table of Contents

Advertisement

240V Wiring Diagram with Optional Built-In Low Voltage Control
Blue (Common)
Brown (Hot)
240VAC 50Hz
Green
Ground–Must be
Connected to
Building Ground
ILT RJ-9 Pin-Outs
IR or Up
Ground Common
+5V
Data or Down
Screen Adjustment For 220V/240V Screens with A Built-In Low Voltage Control
1. Remove the cover plate from the 3-button wall switch and
remove the switch from the junction box.
2. Locate small 3-position switch on back of wall switch.
(See Figure 6)
3. To adjust the down limit switch, slide the 3-position switch to
the down position. Press and hold the down button to run the
screen down to the desired stop position. Release the button
to stop the screen. DO NOT PUSH THE STOP BUTTON.
4. When the screen is in the desired down position, slide the
3-position switch to the off (center) position. The down limit
switch is now set.
5. To adjust the up limit switch, slide the 3-position switch to the
up position. Press and hold the up button to run the screen
up to the desired stop position. Release the button to stop
the screen. DO NOT PUSH THE STOP BUTTON.
6
Green
Ground to Case
(Tab Is Facing Up)
Black
Red
Green
White
Connect Supplied RJ9 Cable
to Splitter and Switch, or use
4 Cable Conductor to Connect
Optional IR and RF
Remote Control
Motor
RJ9
Splitter
Dry Contacts
IMPORTANT NOTE: The wall switch is REQUIRED to make
any limit switch adjustments, EVEN if a third party control
system is used. Therefore, it is advised to wire the switch or
provide a 4-conductor connection that is accessible.
Figure 6
6. When the screen is in the desired up position, slide the
3-position switch to the off (center) position. The up limit
switch is now set.
7. To test limit switch setting, make sure the 3-position switch
is in the off (center) position. Press and release the up or
down button on the wall switch to operate the screen.
8. Replace switch and cover plate on the wall.
NOTE: If stop button is pressed, the wall switch will reverse
direction. To correct this, press the stop button again. This
will reset the switch. You will have to re-set both the up
and the down settings.
IMPORTANT NOTE: The wall switch is REQUIRED to make
any limit switch adjustments, EVEN if a third party control
system is used. Therefore, it is advised to wire the switch or
provide a 4-conductor connection that is accessible.
to Screw Terminals.
Low-Voltage Wall Switch
Up
RJ9
Stop
Down
Front
UP DN
GND +5V
3-Position
RJ9
Switch