Emerson XC1008D Installing And Operating Instructions page 63

Table of Contents

Advertisement

Nome
XC
XC
1008
1011
D
D
-
NO
O12
-
25.0
O13
O14
-
15.0
4.20mA 4.20mA 4.20mA
1Q1
1Q2
nu
nu
Pbc1
Pbc1
1Q3
1Q4
0.0
0.0
100.0
100.0
1Q5
30
50
1Q6
1Q7
40
50
40
60
1Q8
40
50
1Q9
40
50
1Q10
1Q11
50
50
0
0
1Q12
1Q13
60
60
10
10
1Q14
1Q15
0
2
150
5
1Q16
10
5
1Q17
5
5
1Q18
4.0
4.0
1Q19
1Q20
350
350
0.0
0.0
1Q21
1Q22
4.0
4.0
1Q24
0
0
255
255
1Q25
1Q26
2
2
-
nu
2Q1
2Q2
-
Pbc2
-
0.0
2Q3
2Q4
-
100.0
2Q5
-
50
-
50
2Q6
2Q7
-
60
2Q8
-
50
2Q9
-
50
1592021021 XC1008-1011-1015D GB A5 r.1.5A 12.10.2009
XC
Level Description
1015
D
NO
Pr2
Dynamic set enabled - circuit 2
25.0
Pr2
Minimum condens. set - circuit 2
15.0
Pr2
Differential dynamic set-circuit 2
Pr1
Analog outputs 1-2 setting
nu
Pr1
Analog output 1 function
Pbc1
Pr1
Probe for analog output 1
0.0
Pr1
Lower limit for analog output 1
100.0
Pr1
Upper limit for analog output 1
50
Pr1
Minimum value for analog output 1
50
Pr1
Analog output 1 value after compressor
start
60
Pr1
Analog output 1 value after compressor
off
50
Pr1
Exclusion band start value 1
50
Pr1
Exclusion band end value 1
50
Pr1
Safety value for Analog output 1
0
Pr1
Regulation delay after exit from neutral
zone
60
Pr1
Analog output 1 rise time
10
Pr1
Analog output 1 permanency before
load activation
2
Pr1
Analog output 1 decreasing delay
5
Pr1
Analog output 1 decreasing time
5
Pr1
Analog output 1 permanency before
load off
5
Pr1
Analog output 1 decreasing time after
load off
4.0
Pr1
Regulation band width 1
350
Pr1
Integral time 1
0.0
Pr1
Band offset 1
4.0
Pr1
Anti reset wind-up 1
0
Pr1
Minimum capacity of inverter 1
255
Pr1
Maximum time at minimum capacity of
inverter 1
2
Pr1
Time at maximum capacity of inverter 1 1÷255min
nu
Pr1
Analog output 2 function
Pbc2
Pr1
Probe for analog output 2
0.0
Pr1
Lower limit for analog output 2
100.0
Pr1
Upper limit for analog output 2
50
Pr1
Minimum value for analog output 2
50
Pr1
Analog output 2 value after compressor
start
60
Pr1
Analog output 2 value after compressor
off
50
Pr1
Exclusion band start value 2
50
Pr1
Exclusion band end value 2
300÷300 (°F) -90÷90
no - YES
F6÷SETF2
(BAR) -20.00÷20.00 (°C) -50.0÷50.0 (PSI) -
300÷300 (°F) -90÷90
4.20 mA (0) - 0.10 V (1)
FREE – CPR - CPR2 - FAN - FAN2 - INVF1 -
INVF2 - nu
Pbc1(0) - Pbc2(1) ; used only with 1Q2 = 0
-1÷100.00 bar; -15÷750PSI; -50÷150°C; -
58÷302°F;
-1÷100.00 bar; -15÷750PSI; -50÷150°C; -
58÷302°F;
0 ÷ 100 %
1Q6 ÷ 100 %
1Q6 ÷ 100 %
1Q7 ÷ 100 %
1Q9 ÷ 100 %
0 ÷ 100 (%)
0 ÷ 255 (sec)
0 ÷ 255 (sec)
0 ÷ 255 (sec)
0 ÷ 255 (sec)
0 ÷ 255 (sec)
0 ÷ 255 (sec)
0 ÷ 255 (sec)
0.10÷25.00bar; 0.0÷25.0°C; 1÷250 PSI;
1÷250°F;10÷2500 KPA
0÷999s; with 0 integral action excluded
(-12.0÷12.0°C -12.00 ÷ 12.00BAR, -
120÷120°F, -120÷120PSI; -1200÷1200KPA
0.0÷99.0 °C; 0÷180°F; 0.00÷50,00bar;
0÷725PSI; 0÷5000kPA
0÷99%; with 0 function excluded
1÷255min
FREE – CPR - CPR2 - FAN - FAN2 - INVF1 -
INVF2 - nu
Pbc1(0) - Pbc2(1) ; usata solo quando 2Q2 = 0
-1÷100.00 bar; -15÷750PSI; -50÷150°C; -
58÷302°F;
-1÷100.00 bar; -15÷750PSI; -50÷150°C; -
58÷302°F;
0 ÷ 100 (%)
2Q5 ÷ 100 %
2Q5 ÷ 100 %
2Q6 ÷ 100 %
2Q8 ÷ 100 %
XC1008-1011-1015D
Range
63/66