Weller WD 1 Operating Manual page 6

Table of Contents

Advertisement

6-18
4.2
Technical data WD 1 (M) / WD 1000 (M)
Dimensions
Weight
Mains supply voltage
Power consumption
Safety class
Fuse (12)
Only WD 1 / WD 1000
Fuse (12)
Only WD 1 M/ WD 1000M
Temperature control
Temperature accuracy
Temperature stability
Soldering tip leakage
resistance (tip to ground)
Soldering tip leakage
current (tip to ground)
Equipotential bonding
Equipotential bonding
4 variants are possible through connecting the 3.5 mm pawl
socket (8) differently:
− Hard earthed/grounded: without connector (delivery status)
− Equipotential bonding: with connector, bonding line at central
contact
− Floating: with connector
− Soft earthed/grounded: with connector and soldered resistor.
Earthing/grounding via the selected resistor
USB port
The control units WD 1M and WD 1000M are fitted with a mini USB
interface (10). For the purpose of using the USB port, Weller
software is available on a CD with which you
− can carry out a software update ("Firmware Updater") on your
control unit and
− can remote-control the control unit and graphically display, store
and print temperature curves ("Monitor Software").
Note
Control units WD 1 and WD 1000 can be retrofitted with a USB
interface.
WD 1 (M) / WD 1000 (M)
L x W x H (mm): 134 x 108 x 147
L x W x H (inches): 5.27 x 4.27 x 5.77
approx. 3.4 kg
230 V, 50/60 Hz
120 V, 60 Hz
100 V, 50/60 Hz
95 W
I and III, housing antistatic
T 500 mA (230 V, 50 / 60 Hz)
T 1.0 A (120 V, 60 Hz)
T 1.25 A (100 V, 50 / 60 Hz)
T 800 mA (230 V, 50 / 60 Hz)
T 1.6 A (120 V, 60 Hz)
T 1.6 A (100 V, 50 Hz)
50 °C – 450 °C (150 °F – 842 °F)
± 9 °C (± 17 °F)
± 5 °C (± 9 °F)
Complies with IPC-J-001D
Complies with IPC-J-001D
Via 3.5 mm pawl socket on back of
device (8).

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wd 1000m

Table of Contents