BASIC MODE

MODEL RAS-25CNH11
Operation mode
Fan
Basic
operation of
Start/Stop
switch
OFF-timer
ON-timer
Table 3 Room temp. shift value
Table 2 Room temp. shift value
Operation mode
Shift value
Operation mode
Heating
Normal
SHIFTW
Normal
SHIFTC
Cooling,
dehumidifying
Cool Rhythm
SFTRZM
Heating
Cooling
Dehumidifying
Note:
1. Refer to data in Table 1 and 2 for constants shown by capital letters in Table 3.
Cooling
Dehumidifying
Start
Stop
Start
Stop
Start / stop switch
Operation lamp
Start / stop switch
Reserve switch
Cancel switch
Operation lamp
Timer lamp
Timer memory
(OFF — timer in the stop mode)
(Reserved time change)
Start / stop switch
Reserve switch
Cancel switch
Operation lamp
Timer lamp
Timer memory
(Reserved time change)
(ON — timer in the operation mode)
Voltage set
Fan speed tap
Label name
value
Super Lo
AFWSS
9.8V
Lo
AFWS
16.6V
Overload
AFWKAF
19.1V
Med
AFWL
19.1V
Hi
AFWH
27.7V
Super Hi
AFWHH
27.7V
Lo
AFCS
16.0V
Med
AFCL
18.7V
Hi
AFCH
20.9V
Super Hi
AFCHH
20.9V
Lo
AFDS
16.0V
Med
AFDL
18.7V
Super Lo
AFDSS
15.0V
Heating
Auto
Table 1
Model
RAS-25CNH11
Data
Source
Label
Required value of
file name
name
unit side
WMAX
5400 min
-1
WSTD
4700 min
-1
CMAX
4000 min
-1
-1
CSTD
4000 min
CKYMAX
2500 min
-1
CJKMAX
2500 min
-1
-1
COYMAX
2450 min
WMIN
1950 min
-1
-1
CMIN
1950 min
DMIN
1950 min
-1
SDMAX
2500 min
-1
SDRPM
2150 min
-1
SHIFTW
1.33 ˚C
SHIFTC
0 ˚C
SFTRZM
2.0 ˚C
YNEOF
24 ˚C
TEION
5 ˚C
TEIOF
9 ˚C
TDSFNP
5 ˚C
CLMXTP
30 ˚C
DFTIM
40 min.
TDF411
57 sec.
TDF412
Above value+37 sec.
TDF413
Above value+ 0 sec.
TDF421
60 sec.
TDF422
3900 min
-1
TDF431
75 sec.
SITUA
0.3
SITUB
5.67 ˚C
SFTDSW
1.33 ˚C
KAFON
48 ˚C
KAFOF
42 ˚C
– 41 –