Operations
NOTICE
The following section was designed to give
instructions on the basic operations of this table saw.
However, it is in no way comprehensive of every table
saw application. It is strongly recommended that you
read books, trade magazines, or get formal training to
maximize the potential of your table saw and to
minimize the risks.
A
Mitre Gauge Operation
1. Operate Mitre gauge by loosening lock knob(A),
C
pull out spring loaded plunger (B) and rotate mitre
gauge body (C) to desired angle. See example at
right.
2. Release plunger and tighten lock knob.
B
Note: Always make test cuts. Do not rely solely on
mitre gauge indictor marks.
Blade Raising and Tilting
Mechanism
To raise or lower the saw blade, loosen the lock knob
or lever (mounted in the middle or behind the blade
height adjusting handwheel) and turn the handwheel
on the saw front until desired height is reached.
Tighten lock knob/lever.
To tilt the saw blade, loosen the lock knob or lever
(mounted in the middle or behind the blade angle
adjusting handwheel) and turn the handwheel on the
saw front until desired angle is reached. Tighten lock
knob/lever.
Rip Fence Operation
Release the clamping pressure of the fence by raising
the fence lock lever. Move fence to desired position by
sliding the fence assembly. Lock the fence into
position by pushing down on the fence locking lever,
until the clamping press is sufficiant to prevent the
fence assembly from moving. Adjustments can be
made to both the alignment and clamping pressure on
the fence assembly, please refer to the assembly
section.
ON/OFF Switch
On and off switches are normally thermally protected.
If the saw motor is overloaded, or a momentary inter-
ruption of electrical current is sensed, the saw will shut
WARNING
off. Allow a few minutes for the saw to cool down and
reset by pushing the off button.
Always wear a Australian Standards
Using extension cords can cause a loss in power to
approved dust mask to prevent inhaling
your machine. It is best if the saw is plugged directly
dangerous dust or airborne particles.
into an outlet on a dedicated circuit.