5 0
Thermostat (Part # 99300650)
!
Do not connect 120 VAC to the gas control valve or wiring of this unit.
+
It is easiest to route the remote control wire prior to installing the fireplace. Route the wire to a location
near the gas inlet. Allow 3' of wire for hookup inside the fireplace.
1
Attach the thermostat wire and route through the gas inlet hole (see the illustration below).
through all the slack (you may wish to wrap the wire in electrical tape to prevent damaging the wire).
2
Determine a location for the thermostat that is within range of the 50' length of thermostat wire. It
should be centralized in the room and away from the heater. The wire may be routed externally on the
wall or behind the wall (preferred).
3
Install the thermostat following the directions below.
d
Attach the thermostat to
the wall through these
two holes.
e
Re-attach the cover
removed in step ÒaÓ.
Travis Industries
Optional Equipment
Side of
Fireplace
Green
Jumper
Wire
b
Route the wire through
Faceplate
the gas inlet hole
50
60
70
80
90
Robertshaw
Wire
4
1
5
2
Back of on/off switch
a
Remove and discard the jumper wire on the back of the
on/off switch. Attach the quick connects on the end of the
wire to the two posts the jumper wire was attached to.
50 60 70 80 90
9 3 5 0 8 1 0 3
Pull
PILOT
ON
IGNITER
OFF
a
Pull the cover off the thermostat
b
Run the thermostat wires
through the wall (cut off excess
wire, leaving 6Ó of slack).
c
Expose 1/2Ó of wire and
attach to these two posts.
Standard
Screwdriver
1 5 1 0 0 2

Hide quick links: