Hor. Terminations With 6-5/8" Dia. Vent - FireplaceXtrordinair 36 DV XL Owner's Manual

Built-in direct vent fireplace
Hide thumbs Also See for 36 DV XL:
Table of Contents

Advertisement

Installation
2 0
Horizontal Terminations using 6-5/8Ó Diameter Vent
Use a single 90¡
elbow (NOTE:
an additional 45¡
elbow may be
used on the
horizontal run).
The termination
must fall within
the shaded area
shown in the
chart. Use the
indicated
restrictor
position.
Travis Industries
(for qualified installers only)
Natural Gas
Installations
9' (max)
5 feet
0 feet
NOTE:
¥ Horizontal sections require a 1/4" rise every 12" of travel.
¥ The maximum vertical length is 5'.
¥ The maximum horizontal length is 12'.
¥ Restrictor positions are based upon lab tests. The ideal restrictor position may vary slightly.
Propane (LP)
Installations
9' (max)
5 feet
0 feet
NOTE:
¥ Horizontal sections require a 1/4" rise every 12" of travel.
¥ The maximum vertical length is 5'.
¥ The maximum horizontal length is 12'.
¥ Restrictor positions are based upon lab tests. The ideal restrictor position may vary slightly.
9 3 5 0 8 1 0 3
Use Restrictor
Position #1
3 foot length (max)
Warning:
When an elbow is used directly off
the top of the fireplace, a 2"
clearance is required above the
vent (1" below and to the sides).
Use Restrictor
Position #1
NOTE:
Units using LP must have a 1'
vertical section directly off the top
of the fireplace.
9' (max)
5 feet
0 feet
9' (max)
5 feet
0 feet
1 5 1 0 0 2