Oki C9600 Service Manual page 177

Hide thumbs Also See for C9600:
Table of Contents

Advertisement

Display
Cause
Power Off/on
Video overrun
073: Error
detect
to
075: Error
Service Call
Parameter Match
081: Error
Check Error
Service Call
Finisher
096: Error
Unrestorable Error
Service Call
Inverter power
097 Error
supply Error
Service Call
When turning ON
the power,
104: Error
detected error in
engine EEPROM
test total.
When turning
Service Call
105: Error
ON the power,
failed to detect
the EEPROM
(presence).
Service Call
Error detected in
106: Error
engine control
logic.
Service Call
An optional unit
111: Error
for another model
to
was detected.
117: Error
111: Duplex unit
112: 2nd Tray
113: 3rd Tray
114: 4th Tray
115: 5th Tray
116: Finisher
117: Inverter
Service Call
Low Voltage
121: Error
Power FAN Error
Service Call
Sensor detects an
123: Error
inappropriate
relative humidity
for the operating
environment.
Service Call
Sensor detects an
124: Error
inappropriate
room temperature
for the operating
environment.
Service Call
Error detected in
125: Error
MPT home
position.
Turn OFF the
Sensor Dew Error
power and wait
for awhile.
126: Dew Error
42930511TH Rev. 2
Table 7-1-1 Operator Alarm (3/10)
Error Description and Analysis
Is the CU Assy properly
mounted?
Does replacement of the CU
PCB correct the problem?
Normal Read/Write not possible
with EEPROM or Flash.
Is the error display
reproducible?
Is the error display
reproducible?
Does the Error take place again?
Is there an EEPROM?
Does the Error take place again?
Does the Error take place again?
Is the proper optional unit for
that model mounted?
1) Is the PU PCB high voltage
power cable properly con-
nected?
2) Does the Error take place
again?
1) Is an Error message dis-
played?
2) Does the Error take place
again?
1) Is an Error message dis-
played?
2) Does the Error take place
again?
1) Is an Error message dis-
played?
2) Does the Error take place
again?
Sensor Dew Error Detected
Oki Data CONFIDENTIAL
Remedy
judgment
No
Properly mount
Replace CU PCB.
Yes
(Must replace EEPROM)
If the condition does not change
replace CU PCB.
If turning OFF and ON the power
again does not correct the
problem, maintenance by a
servicing personnel is necessary.
If turning OFF and ON the power
again does not correct the
problem, maintenance by a
servicing personnel is necessary.
Yes
Replace engine control PCB
(S2V).
Yes
Check to see if there is an
EEPROM. If not, mount an
EEPROM.
No
Mount the EEPROM.
Yes
Replace engine control PCB
(S2V).
Yes
Replace engine control PCB
(S2V).
No
Mount the proper optional unit.
Check the connection. Then turn
No
ON the power again. Replace
the unit if operations is not
restored.
No
Connect properly
Yes
Check to see if there is any
contact-defects in the high
voltage system.
Yes
Replace High Voltage Power Unit
Yes
Turn ON power again.
Yes
Replace the environmental
sensor.
Yes
Turn ON power again.
Yes
Replace the environmental
sensor.
Yes
Turn ON power again.
Yes
Replace MPT
Wait a while then turn ON power
again.
600
1200

-

-






















177 /

Advertisement

Table of Contents
loading

This manual is also suitable for:

C9800

Table of Contents