Scope Of This Manual; Model Identification; Typical Application Examples; Application 1 - Daikin EKHBRD011AAV1 Installation Manual

Indoor unit for air to water heat pump system
Hide thumbs Also See for EKHBRD011AAV1:
Table of Contents

Advertisement

Room thermostat (option)
An optional room thermostat EKRTR or EKRTW can be connected to
the indoor unit.
Refer to the room thermostat installation manual for further details.
If this option is installed it is not possible to use the remote
controller thermostat function.
Digital I/O PCB (option)
An optional EKRP1HBA digital I/O PCB can be connected to the
indoor unit and be used to remotely monitor your system. This
address card offers 3 voltage free outputs.
Refer to the operation manual of the indoor unit and to the digital I/O
PCB installation manual for more information.
Refer to the wiring diagram or connection diagram for connecting this
PCB to the unit.
Demand PCB (option)
An optional EKRP1AHTA demand PCB can be connected to the
indoor unit. This PCB is needed when the Daikin room thermostat
EKRTR or EKRTW is installed or when multiple set point control is
used, and provides the communication with the indoor unit.
Refer to the demand PCB installation manual for further details.
Refer to the wiring diagram or connection diagram for connecting this
PCB to the unit.

Scope of this manual

This installation manual describes the procedures for handling,
installing and connecting all EKHBRD indoor unit models.
NOTE
Installation of the ERSQ or ERRQ heat pump outdoor
is described in the outdoor unit installation manual.
Operation of the indoor unit is described in the indoor
unit operation manual.
Model identification
Indoor unit
EK
HBR
D
016
AA
Indication of heating capacity (kW)
Refrigerant type R134a
Hydro box - high temperature heating only
European kit
(a) For exact values, refer to
"Unit specifications" on page
EKHBRD011~016AAV1+Y1
Indoor unit for air to water heat pump system
4PW54465-1A
V1
V1 = 1N~, 220-240 V, 50 Hz
Y1 = 3N~, 380-415 V, 50 Hz
Series
(a)
34.

Typical application examples

The application examples given below are for illustration purposes
only.

Application 1

Space heating and domestic hot water heating with a single remote
controller installed in the living room.
1
12
2
3
12
5
1
Outdoor unit
2
Indoor unit
3
Refrigerant heat exchanger
4
Water heat exchanger
5
Compressor
6
Pump
7
Shut-off valve
8
Motorized 3-way valve
(optional)
9
Domestic hot water tank
(optional)
The remote controller gives immediate feedback to the indoor unit
and by doing so it matches in a smart way the unit performance to
the demanded space heating requirements. In this way there is no
frequent start/stop of the unit or there are no too big temperature
fluctuations in the to be heated rooms. This remote controller has
also a smart logic functionality which controls the combined space
heating and domestic hot water demand (e.g. if room temperature
drops more than 3°C during domestic hot water operation, the unit
will automatically switch back to space heating). There is no remote
controller near the unit. During service maintenance an additional
remote controller can be connected by a service person.
A
4
6
7 7 10 13
M
8
9
10
Collector (field supply)
11
Radiator (field supply)
12
Electronic expansion
valve
13
By-pass valve (field
supply)
C1
Remote controller
A
Installation place
B
Living room
Installation manual
B
C1
11
2