Install the grommets (accessories) around the knockout
holes to prevent damage.
1
2
1
Knockout hole
2
Burr
Level the unit to a stable position
using the levelling feet.
Close the sound panel(s) and decoration panel(s) which will be
on the wall side and for which fixation is not possible anymore
after the unit is put on its final location.
Fix the sound bottom strips on both sides of the unit with the
appropriate screws.
1
3
Standard installation location of the optional domestic
hot water tank is on top of the indoor unit.
If available service space to left and/or right side is
limited, carefully consider all tank module installation
steps first.
Place the unit in the appropriate installation location.
The weight of the unit is approximately 145 kg. At
least two persons are required to lift the unit.
Use the plates delivered with the unti to lift the unt
Cut the tie wraps to release the flexible pipes.
Installation manual
9
3
4
3
Grommet
4
Putty or insulation
materials (field supply)
3
1
2x
Put the flexible pipes through the knockout holes.
Perform the piping work as described in the chapter
connection work" on page
10.
Fill the system with water as described in the chapter
water" on page
12.
Perform the electrical wiring work as described in the chapter
"Electrical wiring work" on page
To make the casing completely sealed, plug the knockout holes
with putty or insulation materials (to be prepared on-site).
Perform the pre-operation checks as described in the chapter
"Start-up and configuration" on page
Close the unit
Put the sound bottom plate at the bottom of the unit and fix it
with the appropriate screws.
Fix the front and remaining side decoration panel(s) back to
the unit using the appropriate screws.
Fix the top panel on the unit with the appropriate screws.
4x
2
2x
2x
Stick the top plate insulation (accessory) at the inside of the
top decoration panel according to the figure below.