Application 2; Application 3 - Daikin EKHBRD011AAV1 Installation Manual

Indoor unit for air to water heat pump system
Hide thumbs Also See for EKHBRD011AAV1:
Table of Contents

Advertisement

Application 2

Space heating and domestic hot water heating with one remote
controller installed with the unit, and another remote controller
installed in the living room.
C2
1
12
2
3
12
5
1
Outdoor unit
2
Indoor unit
3
Refrigerant heat
exchanger
4
Water heat exchanger
5
Compressor
6
Pump
7
Shut-off valve
8
Motorized 3-way valve
(optional)
9
Domestic hot water tank
(optional)
The remote controller gives immediate feedback to the indoor unit
and by doing so it matches in a smart way the unit performance to
the demanded space heating requirements. In this way there is no
frequent start/stop of the unit or there are no too big temperature
fluctuations in the to be heated rooms. This remote controller has
also a smart logic functionality which controls the combined space
heating and domestic hot water demand (e.g. if room temperature
drops more than 3°C during domestic hot water operation, the unit
will automatically switch back to space heating). The main remote
controller (C1) is installed in the living room and can access all
settings (master). The second remote controller (C2) can not access
schedule and parameter settings (slave).
Operation ON/OFF
Domestic water heating operation ON/OFF
Setting the leaving water temperature
Setting the room temperature
Quiet mode ON/OFF
Weather dependent set point operation
ON/OFF
Setting the clock
Programming the schedule timer
Schedule timer operation ON/OFF
Field settings
Error code display
Test operation
Room thermostat functionality
Refer to the chapter
"Electrical wiring work" on page 13
connecting the master and slave remote controller.
Installation manual
3
A
4
6
7 7
10 13
M
8
9
10
Collector (field supply)
11
Radiator (field supply)
12
Electronic expansion valve
13
By-pass valve (field
supply)
C1
Remote controller (master)
C2
Optional remote controller
(slave)
A
Installation place
B
Living room
Master
Slave
Operable
Operable
Operable
Operable
Operable
Operable
Operable
Operable
Operable
Operable
Operable
Operable
Operable
Operable
Operable
Operable
Operable
Operable
Operable
Operable
Operable
Operable

Application 3

Space heating and domestic hot water heating with a single remote
controller installed with the unit, and the external room thermostat
installed in the living room.
B
Optionally the Daikin room thermostat EKRTR or EKRTW
can be connected to the Daikin system. Daikin can not
C1
guarantee neither good operation nor reliability of the
system if another thermostat is used. For those reasons
Daikin can not give warranty of the system in such case.
11
1
12
1
Outdoor unit
2
Indoor unit
3
Refrigerant heat exchanger
4
Water heat exchanger
5
Compressor
6
Pump
7
Shut-off valve
8
Motorized 3-way valve
(optional)
9
Domestic hot water tank
(optional)
There is only a room thermostat on/off control. There is no smart
logic functionality for space heating. The domestic hot water
operation is performed according to the minimum and maximum
timer operation.
about
C1
2
3
12
4
6
7 7
10 13
M
5
8
10
Collector (field supply)
11
Radiator (field supply)
12
Electronic expansion
valve
13
By-pass valve (field
supply)
C1
Remote controller
T
Room thermostat
A
Installation place
B
Living room
EKHBRD011~016AAV1+Y1
Indoor unit for air to water heat pump system
A
B
T
11
9
4PW54465-1A

Hide quick links:

Advertisement

Table of Contents